提交 41b4b3bc 编写于 作者: G Geert Uytterhoeven 提交者: Simon Horman

drivers: sh: Disable PM runtime for multi-platform sh73a0 with genpd

If the default PM domain using PM_CLK is used for PM runtime, the real PM
domain(s) cannot be registered from DT later.

Hence do not enable it when running a multi-platform kernel with genpd
support on an sh73a0. The R-Mobile PM domain driver will take care of
PM runtime management of the module clocks.

The default PM domain is still needed for:
  - platforms without genpd support,
  - the legacy (non-DT) case, where genpd may take over later, except
    for the C5 "always on" PM domain.
Signed-off-by: NGeert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: NSimon Horman <horms+renesas@verge.net.au>
上级 b787f68c
......@@ -83,6 +83,7 @@ static int __init sh_pm_runtime_init(void)
!of_machine_is_compatible("renesas,r8a73a4") &&
#ifndef CONFIG_PM_GENERIC_DOMAINS_OF
!of_machine_is_compatible("renesas,r8a7740") &&
!of_machine_is_compatible("renesas,sh73a0") &&
#endif
!of_machine_is_compatible("renesas,r8a7778") &&
!of_machine_is_compatible("renesas,r8a7779") &&
......@@ -91,8 +92,7 @@ static int __init sh_pm_runtime_init(void)
!of_machine_is_compatible("renesas,r8a7792") &&
!of_machine_is_compatible("renesas,r8a7793") &&
!of_machine_is_compatible("renesas,r8a7794") &&
!of_machine_is_compatible("renesas,sh7372") &&
!of_machine_is_compatible("renesas,sh73a0"))
!of_machine_is_compatible("renesas,sh7372"))
return 0;
}
......