提交 4044ba58 编写于 作者: N NeilBrown

md: don't retry recovery of raid1 that fails due to error on source drive.

If a raid1 has only one working drive and it has a sector which
gives an error on read, then an attempt to recover onto a spare will
fail, but as the single remaining drive is not removed from the
array, the recovery will be immediately re-attempted, resulting
in an infinite recovery loop.

So detect this situation and don't retry recovery once an error
on the lone remaining drive is detected.

Allow recovery to be retried once every time a spare is added
in case the problem wasn't actually a media error.
Signed-off-by: NNeilBrown <neilb@suse.de>
上级 efeb53c0
...@@ -1500,6 +1500,9 @@ static int bind_rdev_to_array(mdk_rdev_t * rdev, mddev_t * mddev) ...@@ -1500,6 +1500,9 @@ static int bind_rdev_to_array(mdk_rdev_t * rdev, mddev_t * mddev)
list_add_rcu(&rdev->same_set, &mddev->disks); list_add_rcu(&rdev->same_set, &mddev->disks);
bd_claim_by_disk(rdev->bdev, rdev->bdev->bd_holder, mddev->gendisk); bd_claim_by_disk(rdev->bdev, rdev->bdev->bd_holder, mddev->gendisk);
/* May as well allow recovery to be retried once */
mddev->recovery_disabled = 0;
return 0; return 0;
fail: fail:
...@@ -6175,7 +6178,7 @@ static int remove_and_add_spares(mddev_t *mddev) ...@@ -6175,7 +6178,7 @@ static int remove_and_add_spares(mddev_t *mddev)
} }
} }
if (mddev->degraded && ! mddev->ro) { if (mddev->degraded && ! mddev->ro && !mddev->recovery_disabled) {
list_for_each_entry(rdev, &mddev->disks, same_set) { list_for_each_entry(rdev, &mddev->disks, same_set) {
if (rdev->raid_disk >= 0 && if (rdev->raid_disk >= 0 &&
!test_bit(In_sync, &rdev->flags) && !test_bit(In_sync, &rdev->flags) &&
......
...@@ -1016,12 +1016,16 @@ static void error(mddev_t *mddev, mdk_rdev_t *rdev) ...@@ -1016,12 +1016,16 @@ static void error(mddev_t *mddev, mdk_rdev_t *rdev)
* else mark the drive as failed * else mark the drive as failed
*/ */
if (test_bit(In_sync, &rdev->flags) if (test_bit(In_sync, &rdev->flags)
&& (conf->raid_disks - mddev->degraded) == 1) && (conf->raid_disks - mddev->degraded) == 1) {
/* /*
* Don't fail the drive, act as though we were just a * Don't fail the drive, act as though we were just a
* normal single drive * normal single drive.
* However don't try a recovery from this drive as
* it is very likely to fail.
*/ */
mddev->recovery_disabled = 1;
return; return;
}
if (test_and_clear_bit(In_sync, &rdev->flags)) { if (test_and_clear_bit(In_sync, &rdev->flags)) {
unsigned long flags; unsigned long flags;
spin_lock_irqsave(&conf->device_lock, flags); spin_lock_irqsave(&conf->device_lock, flags);
......
...@@ -218,6 +218,9 @@ struct mddev_s ...@@ -218,6 +218,9 @@ struct mddev_s
#define MD_RECOVERY_FROZEN 9 #define MD_RECOVERY_FROZEN 9
unsigned long recovery; unsigned long recovery;
int recovery_disabled; /* if we detect that recovery
* will always fail, set this
* so we don't loop trying */
int in_sync; /* know to not need resync */ int in_sync; /* know to not need resync */
struct mutex reconfig_mutex; struct mutex reconfig_mutex;
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册