提交 3e782985 编写于 作者: A Andrew Lunn 提交者: David S. Miller

net: ethernet: fec: Allow configuration of MDIO bus speed

MDIO busses typically operate at 2.5MHz. However many devices can
operate at faster speeds. This then allows more MDIO transactions per
second, useful for Ethernet switch statistics, or Ethernet PHY TDR
data. Allow the bus speed to be configured, using the standard
"clock-frequency" property, which i2c busses use to indicate the bus
speed. Before using this property, ensure all devices on the bus do
actually support the requested clock speed.
Suggested-by: NChris Healy <Chris.Healy@zii.aero>
Signed-off-by: NAndrew Lunn <andrew@lunn.ch>
Reviewed-by: NFlorian Fainelli <f.fainelli@gmail.com>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 29ae6bd1
......@@ -82,6 +82,7 @@ ethernet@83fec000 {
phy-supply = <&reg_fec_supply>;
phy-handle = <&ethphy>;
mdio {
clock-frequency = <5000000>;
ethphy: ethernet-phy@6 {
compatible = "ethernet-phy-ieee802.3-c22";
reg = <6>;
......
......@@ -39,6 +39,12 @@ properties:
and must therefore be appropriately determined based on all PHY
requirements (maximum value of all per-PHY RESET pulse widths).
clock-frequency:
description:
Desired MDIO bus clock frequency in Hz. Values greater than IEEE 802.3
defined 2.5MHz should only be used when all devices on the bus support
the given clock speed.
patternProperties:
"^ethernet-phy@[0-9a-f]+$":
type: object
......
......@@ -2067,6 +2067,7 @@ static int fec_enet_mii_init(struct platform_device *pdev)
struct device_node *node;
int err = -ENXIO;
u32 mii_speed, holdtime;
u32 bus_freq;
/*
* The i.MX28 dual fec interfaces are not equal.
......@@ -2094,15 +2095,20 @@ static int fec_enet_mii_init(struct platform_device *pdev)
return -ENOENT;
}
bus_freq = 2500000; /* 2.5MHz by default */
node = of_get_child_by_name(pdev->dev.of_node, "mdio");
if (node)
of_property_read_u32(node, "clock-frequency", &bus_freq);
/*
* Set MII speed to 2.5 MHz (= clk_get_rate() / 2 * phy_speed)
* Set MII speed (= clk_get_rate() / 2 * phy_speed)
*
* The formula for FEC MDC is 'ref_freq / (MII_SPEED x 2)' while
* for ENET-MAC is 'ref_freq / ((MII_SPEED + 1) x 2)'. The i.MX28
* Reference Manual has an error on this, and gets fixed on i.MX6Q
* document.
*/
mii_speed = DIV_ROUND_UP(clk_get_rate(fep->clk_ipg), 5000000);
mii_speed = DIV_ROUND_UP(clk_get_rate(fep->clk_ipg), bus_freq * 2);
if (fep->quirks & FEC_QUIRK_ENET_MAC)
mii_speed--;
if (mii_speed > 63) {
......@@ -2148,7 +2154,6 @@ static int fec_enet_mii_init(struct platform_device *pdev)
fep->mii_bus->priv = fep;
fep->mii_bus->parent = &pdev->dev;
node = of_get_child_by_name(pdev->dev.of_node, "mdio");
err = of_mdiobus_register(fep->mii_bus, node);
of_node_put(node);
if (err)
......
Markdown is supported