net/mlx5: Read timeout values from DTOR
Replace hard coded timeouts with values stored by firmware in default timeouts register (DTOR). Timeouts are read during driver load. If DTOR is not supported by firmware then fallback to hard coded defaults instead. Signed-off-by: NAmir Tzin <amirtz@nvidia.com> Reviewed-by: NMoshe Shemesh <moshe@nvidia.com> Signed-off-by: NSaeed Mahameed <saeedm@nvidia.com>