clocksource/drivers/riscv: Fix clocksource mask
For all riscv architectures (RV32, RV64 and RV128), the clocksource is a 64 bit incrementing counter. Fix the clock source mask accordingly. Tested on both 64bit and 32 bit virt machine in QEMU. Fixes: 62b01943 ("clocksource: new RISC-V SBI timer driver") Signed-off-by: NAtish Patra <atish.patra@wdc.com> Signed-off-by: NThomas Gleixner <tglx@linutronix.de> Reviewed-by: NAnup Patel <anup@brainfault.org> Cc: Albert Ou <aou@eecs.berkeley.edu> Cc: Daniel Lezcano <daniel.lezcano@linaro.org> Cc: linux-riscv@lists.infradead.org Cc: Palmer Dabbelt <palmer@sifive.com> Cc: Anup Patel <Anup.Patel@wdc.com> Cc: Damien Le Moal <Damien.LeMoal@wdc.com> Cc: stable@vger.kernel.org Link: https://lkml.kernel.org/r/20190322215411.19362-1-atish.patra@wdc.com