提交 2d5fbef0 编写于 作者: R Russell King 提交者: David S. Miller

net: phylink: ensure manual flow control is selected appropriately

Split the application of manually controlled flow control modes from
phylink_resolve_flow(), so that we can use alternative providers of
flow control resolution.

We also want to clear the MLO_PAUSE_AN flag when autoneg is disabled,
since flow control can't be negotiated in this circumstance.
Signed-off-by: NRussell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: NAndrew Lunn <andrew@lunn.ch>
Signed-off-by: NDavid S. Miller <davem@davemloft.net>
上级 8cdfa256
......@@ -339,6 +339,18 @@ static int phylink_parse_mode(struct phylink *pl, struct fwnode_handle *fwnode)
return 0;
}
static void phylink_apply_manual_flow(struct phylink *pl,
struct phylink_link_state *state)
{
/* If autoneg is disabled, pause AN is also disabled */
if (!state->an_enabled)
state->pause &= ~MLO_PAUSE_AN;
/* Manual configuration of pause modes */
if (!(pl->link_config.pause & MLO_PAUSE_AN))
state->pause = pl->link_config.pause;
}
static void phylink_mac_config(struct phylink *pl,
const struct phylink_link_state *state)
{
......@@ -408,25 +420,20 @@ static void phylink_resolve_flow(struct phylink *pl,
struct phylink_link_state *state)
{
int new_pause = 0;
int pause = 0;
if (pl->link_config.pause & MLO_PAUSE_AN) {
int pause = 0;
if (phylink_test(pl->link_config.advertising, Pause))
pause |= MLO_PAUSE_SYM;
if (phylink_test(pl->link_config.advertising, Asym_Pause))
pause |= MLO_PAUSE_ASYM;
if (phylink_test(pl->link_config.advertising, Pause))
pause |= MLO_PAUSE_SYM;
if (phylink_test(pl->link_config.advertising, Asym_Pause))
pause |= MLO_PAUSE_ASYM;
pause &= state->pause;
pause &= state->pause;
if (pause & MLO_PAUSE_SYM)
new_pause = MLO_PAUSE_TX | MLO_PAUSE_RX;
else if (pause & MLO_PAUSE_ASYM)
new_pause = state->pause & MLO_PAUSE_SYM ?
MLO_PAUSE_TX : MLO_PAUSE_RX;
} else {
new_pause = pl->link_config.pause & MLO_PAUSE_TXRX_MASK;
}
if (pause & MLO_PAUSE_SYM)
new_pause = MLO_PAUSE_TX | MLO_PAUSE_RX;
else if (pause & MLO_PAUSE_ASYM)
new_pause = state->pause & MLO_PAUSE_SYM ?
MLO_PAUSE_TX : MLO_PAUSE_RX;
state->pause &= ~MLO_PAUSE_TXRX_MASK;
state->pause |= new_pause;
......@@ -494,6 +501,7 @@ static void phylink_resolve(struct work_struct *w)
case MLO_AN_PHY:
link_state = pl->phy_state;
phylink_resolve_flow(pl, &link_state);
phylink_apply_manual_flow(pl, &link_state);
phylink_mac_config_up(pl, &link_state);
break;
......@@ -518,6 +526,7 @@ static void phylink_resolve(struct work_struct *w)
* the pause mode bits. */
link_state.pause |= pl->phy_state.pause;
phylink_resolve_flow(pl, &link_state);
phylink_apply_manual_flow(pl, &link_state);
phylink_mac_config(pl, &link_state);
}
break;
......@@ -1006,7 +1015,6 @@ void phylink_start(struct phylink *pl)
* a fixed-link to start with the correct parameters, and also
* ensures that we set the appropriate advertisement for Serdes links.
*/
phylink_resolve_flow(pl, &pl->link_config);
phylink_mac_config(pl, &pl->link_config);
/* Restart autonegotiation if using 802.3z to ensure that the link
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册