提交 1e7913ff 编写于 作者: G Gwendal Grignou 提交者: Enric Balletbo i Serra

platform/chrome: cros_ec_lightbar: Reduce ligthbar get version command

By default, the lightbar commands are set to the biggest lightbar command
and response. That length is greater than 128 bytes and may not work on
all machines. But all EC are probed for lightbar by sending a get version
request. Set that request size precisely.

Before the command would be:

  cros_ec_cmd: version: 0, command: EC_CMD_LIGHTBAR_CMD, outsize: 194, insize: 128, result: 0

Afer:

  cros_ec_cmd: version: 0, command: EC_CMD_LIGHTBAR_CMD, outsize: 1, insize: 8, result: 0

Fixes: a8411784 ("mfd: cros_ec: Use a zero-length array for command data")
Signed-off-by: NGwendal Grignou <gwendal@chromium.org>
Signed-off-by: NEnric Balletbo i Serra <enric.balletbo@collabora.com>
上级 81431824
......@@ -116,6 +116,8 @@ static int get_lightbar_version(struct cros_ec_dev *ec,
param = (struct ec_params_lightbar *)msg->data;
param->cmd = LIGHTBAR_CMD_VERSION;
msg->outsize = sizeof(param->cmd);
msg->result = sizeof(resp->version);
ret = cros_ec_cmd_xfer_status(ec->ec_dev, msg);
if (ret < 0 && ret != -EINVAL) {
ret = 0;
......