EDAC, altera: Fix S10 Double Bit Error Notification
Stratix10 Double Bit Error Address was always read from SDRAM Address register instead of each device's Address register. To determine which device had the DBE, cycle through the EDAC devices comparing the DBE value to the db_irq value. Once found, report the DBE Address from the device registers as well as the device name. Finally, notify the system via an SMC call and indicate the panic should result in a system reboot. Change a run-time check to a Stratix10 compile-time check for a clean SMC notification. Fixes: d5fc9125 ("EDAC, altera: Combine Stratix10 and Arria10 probe functions") Signed-off-by: NThor Thayer <thor.thayer@linux.intel.com> Signed-off-by: NBorislav Petkov <bp@suse.de> Cc: James Morse <james.morse@arm.com> Cc: Mauro Carvalho Chehab <mchehab@kernel.org> Cc: linux-edac <linux-edac@vger.kernel.org> Link: https://lkml.kernel.org/r/1552490842-25440-1-git-send-email-thor.thayer@linux.intel.com