提交 12bd2575 编写于 作者: V Ville Syrjala 提交者: Pierre Ossman

at91_mci: Fix byte mode transitions.

The byte mode support fails to clear the byte mode bit in the command
register, possibly leaving byte mode enabled with the counters programmed
in non-byte mode.
Signed-off-by: NVille Syrjala <syrjala@sci.fi>
Signed-off-by: NNicolas Ferre <nicolas.ferre@atmel.com>
Signed-off-by: NPierre Ossman <drzeus@drzeus.cx>
上级 9da3cbaf
......@@ -579,7 +579,7 @@ static void at91_mci_send_command(struct at91mci_host *host, struct mmc_command
ier = AT91_MCI_CMDRDY;
} else {
/* zero block length and PDC mode */
mr = at91_mci_read(host, AT91_MCI_MR) & 0x7fff;
mr = at91_mci_read(host, AT91_MCI_MR) & 0x5fff;
mr |= (data->blksz & 0x3) ? AT91_MCI_PDCFBYTE : 0;
mr |= (block_length << 16);
mr |= AT91_MCI_PDCMODE;
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册