提交 0f510a24 编写于 作者: N Niklas Söderlund 提交者: Daniel Lezcano

thermal: rcar_gen3_thermal: Remove temperature bound

The hardware manual states that the operation of the sensor is not
guaranteed with temperatures above 125°C, not that the readings are
invalid. Remove the bound check and try to deliver temperature readings
even if we are outside the guaranteed operation range.
Signed-off-by: NNiklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Signed-off-by: NDaniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20200117160554.3812787-3-niklas.soderlund+renesas@ragnatech.se
上级 dff6d4f8
......@@ -182,9 +182,7 @@ static int rcar_gen3_thermal_get_temp(void *devdata, int *temp)
tsc->coef.a2);
mcelsius = FIXPT_TO_MCELSIUS(val);
/* Make sure we are inside specifications */
if ((mcelsius < MCELSIUS(-40)) || (mcelsius > MCELSIUS(125)))
return -EIO;
/* Guaranteed operating range is -40C to 125C. */
/* Round value to device granularity setting */
*temp = rcar_gen3_thermal_round(mcelsius);
......