ASoC: Tegra: Don't return mclk_changed from utils_set_rate
Only the clock programming code needs to know whether the clocks changed, and that is encapsulated within tegra_asoc_utils_set_rate(). The machine driver's call to snd_soc_dai_set_sysclk(codec_dai, ...) is safe irrespective of whether the clocks changed. (Applying Mark's TrimSlice review comments to the existing driver) Signed-off-by: NStephen Warren <swarren@nvidia.com> Acked-by: NLiam Girdwood <lrg@ti.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>