由 Kamil Debski 提交于
The following error: "error: incompatible types in conditional expression (different base types)" was reported multiple times for the s5p-mfc driver. This error was caused by two macro definitions - s5p_mfc_hw_call (in s5p_mfc_common.h) and WRITEL (in s5p_mfc_opr_v6.c). In the former case the macro assumed that all ops return a value, but some ops return void. The solution to this problem was the addition of a s5p_mfc_hw_call_void macro. In the latter case the macro used the ?: construction to check whether the address is non zero. This is not necessary after the driver left the development and debugging cycle, so the READL and WRITEL macros were removed. Signed-off-by: NKamil Debski <k.debski@samsung.com> Signed-off-by: NMauro Carvalho Chehab <mchehab@osg.samsung.com>