由 Charles Keepax 提交于
Occasionally we can trigger an interrupt before we have completed impedance measurement, although the valid bit will still be set. This patch spins reading the impedance value until a valid value is seen. Signed-off-by: NCharles Keepax <ckeepax@opensource.wolfsonmicro.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>