由 Tejun Heo 提交于
libata EH used to ignore errors not associated with commands when determining whether speed down is necessary or not. This leads to the following problems. * Errors not associated with commands can occur indefinitely without libata EH taking corrective actions. * Upstream link errors don't trigger speed down when PMP is attached to it and commands issued to downstream device trigger errors on the upstream link. This patch makes ata_eh_link_autopsy() consider errors not associated with command for speed down. Signed-off-by: NTejun Heo <htejun@gmail.com> Signed-off-by: NJeff Garzik <jeff@garzik.org>
dfcc173d