由 Alexander Sverdlin 提交于
S25FL{128|256|512}S datasheets say: "When P_ERR or E_ERR bits are set to one, the WIP bit will remain set to one indicating the device remains busy and unable to receive new operation commands. A Clear Status Register (CLSR) command must be received to return the device to standby mode." Current spi-nor code works until first error occurs, but write/erase errors are not just rare hardware failures, they also occur if user tries to flash write-protected areas. After such attempt no SPI command can be executed any more and even read fails. This patch adds support for P_ERR and E_ERR bits in Status Register 1 (so that operation fails immediately and not after a long timeout) and proper recovery from the error condition. Tested on Spansion S25FS128S, which is supported by S25FL129P entry. Signed-off-by: NAlexander Sverdlin <alexander.sverdlin@nokia.com> Signed-off-by: NCyrille Pitchen <cyrille.pitchen@wedev4u.fr>