由 Jitendra Bhivare 提交于
This is second part of actual fix for soft lockup. All mbox cmds issued using BMBX and MCC are synchronized using mutex mbox_lock instead of spin_lock. Used mutex_lock_interruptible where ever possible. Signed-off-by: NJitendra Bhivare <jitendra.bhivare@avagotech.com> Reviewed-by: NShane Seymour <shane.seymour@hpe.com> Reviewed-by: NHannes Reinicke <hare@suse.de> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>