• Z
    iommu/arm-smmu-v3: Avoid back-to-back CMD_SYNC operations · 901510ee
    Zhen Lei 提交于
    Putting adjacent CMD_SYNCs into the command queue is nonsensical, but
    can happen when multiple CPUs are inserting commands. Rather than leave
    the poor old hardware to chew through these operations, we can instead
    drop the subsequent SYNCs and poll for completion of the first. This
    has been shown to improve IO performance under pressure, where the
    number of SYNC operations reduces by about a third:
    
    	CMD_SYNCs reduced:	19542181
    	CMD_SYNCs total:	58098548	(include reduced)
    	CMDs total:		116197099	(TLBI:SYNC about 1:1)
    Signed-off-by: NZhen Lei <thunder.leizhen@huawei.com>
    Signed-off-by: NWill Deacon <will.deacon@arm.com>
    901510ee