由 Ville Syrjälä 提交于
The registers frobbed by vlv_init_display_clock_gating() libve inside the disp2d power well, so frobbing them while the power well is down results in unclaimed register access warning (and of course the values won't stick). Let's do this setup after we know the power well is enabled. It's also worth noting that DSPCLK_GATE_D and CBR1_VLV lose their state when the power well goes down, but fortunately the values we've been writing are actually the reset defaults. MI_ARB_VLV actually retains its value even if the power well was turned off, we just can't access it while the power well is down. Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=94164Signed-off-by: NVille Syrjälä <ville.syrjala@linux.intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/1460382992-28728-9-git-send-email-ville.syrjala@linux.intel.comReviewed-by: NImre Deak <imre.deak@intel.com>
766078df