由 Jon Cooper 提交于
We don't directly control RX ingress on Siena or any later controllers, and so we cannot prevent packets from entering the RX datapath while the RX queues are not set up. This results in the hardware incrementing RX_NODESC_DROP_CNT, but it's not an error and we should not include it in error stats. When bringing an interface up or down, pull (or wait for) stats and count the number of packets that were dropped while the interface was down. Subtract this from the reported RX dropped count. Signed-off-by: NBen Hutchings <bhutchings@solarflare.com>
f8f3b5ae