由 NeilBrown 提交于
If a RAID5 has both a failed device and a device marked as 'WantReplacement', then we should preferentially replace the failed device. However the current code replaces whichever is found first. So split into 2 loops, check fail failed/missing first, and only check for WantReplacement if nothing is failed or missing. Reported-by: Nmajianpeng <majianpeng@gmail.com> Signed-off-by: NNeilBrown <neilb@suse.de>
5cfb22a1