由 Ivan Khoronzhuk 提交于
Each slave has it's own receive timestamp filter. But cpts rx/tx timestamp enable flags are used to allow ts retrieve only for one user. This limitation causes data path redundancy and setting overlap if cpsw module is in dual-mac mode for instance. If rx ts is enabled only for one port - the second interface must expect every incoming packet to be PTP packet w/o absolutely any reason, and if it's PTP - do unneeded stuff, as rx filter for second port is not set and cpts fifo is not supposed to contain appropriate ts event. That's not correct. So, to fix control overlap and avoid redundant CPU cycles, the patch splits rx/tx ts enable flags between network devices. After the patch, PTP timestamping still should be used for only one port (or PTP id counter has to be different for both ports as cpts IP is common). Signed-off-by: NIvan Khoronzhuk <ivan.khoronzhuk@linaro.org> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
a9423120