-
由 Kashyap, Desai 提交于
(1) EEDP(End to End data protection) was not working. This was due to not setting EEDP BlockSize and Flags to little endian format in the message frame. (2) Some expander sysfs attributes were not getting set properly. The sas format was not getting set due to endian issues with sas_format field in the struct rep_manu_reply. Since sas_format was not set properly, the component_vendor_id, component_revision_id, and component_id were not set. (3) In _transport_smp_handler: we don't need to convert the smid from little endian to cpu prior to calling mpt2sas_base_free_smid, because its allready in cpu format. (4) Some loginfos and ioc status were not xonverted from little endian to cpu. Signed-off-by: NKashyap Desai <kashyap.desai@lsi.com> Signed-off-by: NEric Moore <Eric.moore@lsi.com> Signed-off-by: NJames Bottomley <James.Bottomley@suse.de>
463217bf