• T
    ext4: Add block validity check when truncating indirect block mapped inodes · 1f2acb60
    Theodore Ts'o 提交于
    Add checks to ext4_free_branches() to make sure a block number found
    in an indirect block are valid before trying to free it.  If a bad
    block number is found, stop freeing the indirect block immediately,
    since the file system is corrupt and we will need to run fsck anyway.
    This also avoids spamming the logs, and specifically avoids
    driver-level "attempt to access beyond end of device" errors obscure
    what is really going on.
    
    If you get *really*, *really*, *really* unlucky, without this patch, a
    supposed indirect block containing garbage might contain a reference
    to a primary block group descriptor, in which case
    ext4_free_branches() could end up zero'ing out a block group
    descriptor block, and if then one of the block bitmaps for a block
    group described by that bg descriptor block is not in memory, and is
    read in by ext4_read_block_bitmap().  This function calls
    ext4_valid_block_bitmap(), which assumes that bg_inode_table() was
    validated at mount time and hasn't been modified since.  Since this
    assumption is no longer valid, it's possible for the value
    (ext4_inode_table(sb, desc) - group_first_block) to go negative, which
    will cause ext4_find_next_zero_bit() to trigger a kernel GPF.
    
    Addresses-Google-Bug: #2220436
    Signed-off-by: N"Theodore Ts'o" <tytso@mit.edu>
    1f2acb60