由 Serge Semin 提交于
A bug was introduced by commit b3b57646 ("tty: serial_core: convert uart_open to use tty_port_open"). It caused a constant warning printed into the system log regarding the tty and port counter mismatch: [ 21.644197] ttyS ttySx: tty_port_close_start: tty->count = 1 port count = 2 in case if session hangup was detected so the warning is printed starting from the second open-close iteration. Particularly the problem was discovered in situation when there is a serial tty device without hardware back-end being setup. It is considered by the tty-serial subsystems as a hardware problem with session hang up. In this case uart_startup() will return a positive value with TTY_IO_ERROR flag set in corresponding tty_struct instance. The same value will get passed to be returned from the activate() callback and then being returned from tty_port_open(). But since in this case tty_port_block_til_ready() isn't called the TTY_PORT_ACTIVE flag isn't set (while the method had been called before tty_port_open conversion was introduced and the rest of the subsystem code expected the bit being set in this case), which prevents the uart_hangup() method to perform any cleanups including the tty port counter setting to zero. So the next attempt to open/close the tty device will discover the counters mismatch. In order to fix the problem we need to manually set the TTY_PORT_ACTIVE flag in case if uart_startup() returned a positive value. In this case the hang up procedure will perform a full set of cleanup actions including the port ref-counter resetting. Fixes: b3b57646 "tty: serial_core: convert uart_open to use tty_port_open" Signed-off-by: NSerge Semin <fancer.lancer@gmail.com> Signed-off-by: NGreg Kroah-Hartman <gregkh@linuxfoundation.org>
13b18d35