• J
    cfg80211: clarify BSS probe response vs. beacon data · 0e227084
    Johannes Berg 提交于
    There are a few possible cases of where BSS data came from:
     1) only a beacon has been received
     2) only a probe response has been received
     3) the driver didn't report what it received (this happens when
        using cfg80211_inform_bss[_width]())
     4) both probe response and beacon data has been received
    
    Unfortunately, in the userspace API, a few things weren't there:
     a) there was no way to differentiate cases 1) and 4) above
        without comparing the data of the IEs
     b) the TSF was always from the last frame, instead of being
        exposed for beacon/probe response separately like IEs
    
    Fix this by
       i) exporting a new flag attribute that indicates whether or
          not probe response data has been received - this addresses (a)
      ii) exporting a BEACON_TSF attribute that holds the beacon's TSF
          if a beacon has been received
     iii) not exporting the beacon attributes in case (3) above as that
          would just lead userspace into thinking the data actually came
          from a beacon when that isn't clear
    
    To implement this, track inside the IEs struct whether or not it
    (definitely) came from a beacon.
    
    Reported-by: William Seto
    Signed-off-by: NJohannes Berg <johannes.berg@intel.com>
    0e227084
nl80211.h 169.2 KB