-
由 Webb Scales 提交于
We had a mix of formats used for specifying controller, bus, target, and lun address of devices. change to the format used by the scsi midlayer and upper layer (2:3:0:0) so you can easily follow the information from hpsa to scsi midlayer to sd upper layer. Also add this information: - product ID - vendor ID - RAID level - SSD Smath Path capable and enabled - exposure level (sg-only) Example: hpsa 0000:04:00.0: added scsi 2:0:0:0: Direct-Access HP LOGICAL VOLUME RAID-0 SSDSmartPathCap+ En+ Exp=4 scsi 2:0:0:0: Direct-Access HP LOGICAL VOLUME 10.0 PQ: 0 ANSI: 5 sd 2:0:0:0: [sdr] 12501713072 512-byte logical blocks: (6.40 TB/5.82 TiB) sd 2:0:0:0: [sdr] 4096-byte physical blocks sd 2:0:0:0: [sdr] Attached SCSI disk sd 2:0:0:0: Attached scsi generic sg20 type 0 Reviewed-by: NScott Teel <scott.teel@pmcs.com> Reviewed-by: NKevin Barnett <kevin.barnett@pmcs.com> Reviewed-by: NTomas Henzl <thenzl@redhat.com> Reviewed-by: NHannes Reinecke <hare@Suse.de> Signed-off-by: NRobert Elliott <elliott@hp.com> Signed-off-by: NDon Brace <don.brace@pmcs.com> Reviewed-by: NChristoph Hellwig <hch@lst.de> Signed-off-by: NJames Bottomley <JBottomley@Odin.com>
0d96ef5f