• A
    [media] af9033: fix AF9033 DVBv3 signal strength measurement · 0b0d9628
    Antti Palosaari 提交于
    Previous patch changes used signal strength firmware register from
    0x800048 to 0x80004a in case of AF9033/AF9035 chip. In practice
    reported values were running upside-down, when RR strength increases
    reported value decreases and vice versa. That is because of 0x80004a
    returns values that are dBm scale, but negative RF strength dBm
    returned as positive number.
    
    0x800048 returns 0-100, like percentage
    0x80004a returns 0-255 dBm, without a negative sign
    
    So restore old measurement now.
    
    Cc: Bimow Chen <Bimow.Chen@ite.com.tw>
    Signed-off-by: NAntti Palosaari <crope@iki.fi>
    Signed-off-by: NMauro Carvalho Chehab <mchehab@osg.samsung.com>
    0b0d9628