Kconfig 17.5 KB
Newer Older
L
Linus Torvalds 已提交
1 2 3 4
#
# Network device configuration
#

5
menuconfig NETDEVICES
6
	default y if UML
7
	depends on NET
L
Linus Torvalds 已提交
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
	bool "Network device support"
	---help---
	  You can say N here if you don't intend to connect your Linux box to
	  any other computer at all.

	  You'll have to say Y if your computer contains a network card that
	  you want to use under Linux. If you are going to run SLIP or PPP over
	  telephone line or null modem cable you need say Y here. Connecting
	  two machines with parallel ports using PLIP needs this, as well as
	  AX.25/KISS for sending Internet traffic over amateur radio links.

	  See also "The Linux Network Administrator's Guide" by Olaf Kirch and
	  Terry Dawson. Available at <http://www.tldp.org/guides.html>.

	  If unsure, say Y.

24 25 26
# All the following symbols are dependent on NETDEVICES - do not repeat
# that for each of the symbols.
if NETDEVICES
27

28 29 30
config MII
	tristate

31 32 33
config NET_CORE
	default y
	bool "Network core driver support"
34
	---help---
35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
	  You can say N here if you do not intend to use any of the
	  networking core drivers (i.e. VLAN, bridging, bonding, etc.)

if NET_CORE

config BONDING
	tristate "Bonding driver support"
	depends on INET
	depends on IPV6 || IPV6=n
	---help---
	  Say 'Y' or 'M' if you wish to be able to 'bond' multiple Ethernet
	  Channels together. This is called 'Etherchannel' by Cisco,
	  'Trunking' by Sun, 802.3ad by the IEEE, and 'Bonding' in Linux.

	  The driver supports multiple bonding modes to allow for both high
	  performance and high availability operation.

	  Refer to <file:Documentation/networking/bonding.txt> for more
	  information.

55
	  To compile this driver as a module, choose M here: the module
56
	  will be called bonding.
57

L
Linus Torvalds 已提交
58 59 60 61 62 63 64
config DUMMY
	tristate "Dummy net driver support"
	---help---
	  This is essentially a bit-bucket device (i.e. traffic you send to
	  this device is consigned into oblivion) with a configurable IP
	  address. It is most commonly used in order to make your currently
	  inactive SLIP address seem like a real address for local programs.
65 66
	  If you use SLIP or PPP, you might want to say Y here. It won't
	  enlarge your kernel. What a deal. Read about it in the Network
L
Linus Torvalds 已提交
67 68 69 70
	  Administrator's Guide, available from
	  <http://www.tldp.org/docs.html#guide>.

	  To compile this driver as a module, choose M here: the module
A
Alan Cox 已提交
71
	  will be called dummy.
L
Linus Torvalds 已提交
72

73 74
config EQUALIZER
	tristate "EQL (serial line load balancing) support"
L
Linus Torvalds 已提交
75
	---help---
76 77 78 79 80 81 82
	  If you have two serial connections to some other computer (this
	  usually requires two modems and two telephone lines) and you use
	  SLIP (the protocol for sending Internet traffic over telephone
	  lines) or PPP (a better SLIP) on them, you can make them behave like
	  one double speed connection using this driver.  Naturally, this has
	  to be supported at the other end as well, either with a similar EQL
	  Linux driver or with a Livingston Portmaster 2e.
L
Linus Torvalds 已提交
83

84 85 86 87
	  Say Y if you want this and read
	  <file:Documentation/networking/eql.txt>.  You may also want to read
	  section 6.2 of the NET-3-HOWTO, available from
	  <http://www.tldp.org/docs.html#howto>.
L
Linus Torvalds 已提交
88

89 90 91 92 93 94 95 96 97 98 99 100 101 102 103
	  To compile this driver as a module, choose M here: the module
	  will be called eql.  If unsure, say N.

config NET_FC
	bool "Fibre Channel driver support"
	depends on SCSI && PCI
	help
	  Fibre Channel is a high speed serial protocol mainly used to connect
	  large storage devices to the computer; it is compatible with and
	  intended to replace SCSI.

	  If you intend to use Fibre Channel, you need to have a Fibre channel
	  adaptor card in your computer; say Y here and to the driver for your
	  adaptor below. You also should have said Y to "SCSI support" and
	  "SCSI generic support".
L
Linus Torvalds 已提交
104

105 106 107 108 109 110
config IFB
	tristate "Intermediate Functional Block support"
	depends on NET_CLS_ACT
	---help---
	  This is an intermediate driver that allows sharing of
	  resources.
L
Linus Torvalds 已提交
111
	  To compile this driver as a module, choose M here: the module
112 113 114 115 116
	  will be called ifb.  If you want to use more than one ifb
	  device at a time, you need to compile this driver as a module.
	  Instead of 'ifb', the devices will then be called 'ifb0',
	  'ifb1' etc.
	  Look at the iproute2 documentation directory for usage etc
L
Linus Torvalds 已提交
117

118 119
source "drivers/net/team/Kconfig"

P
Patrick McHardy 已提交
120
config MACVLAN
121
	tristate "MAC-VLAN support"
P
Patrick McHardy 已提交
122 123 124 125
	---help---
	  This allows one to create virtual interfaces that map packets to
	  or from specific MAC addresses to a particular interface.

126 127 128 129 130
	  Macvlan devices can be added using the "ip" command from the
	  iproute2 package starting with the iproute2-2.6.23 release:

	  "ip link add link <real dev> [ address MAC ] [ NAME ] type macvlan"

P
Patrick McHardy 已提交
131 132 133
	  To compile this driver as a module, choose M here: the module
	  will be called macvlan.

A
Arnd Bergmann 已提交
134
config MACVTAP
135
	tristate "MAC-VLAN based tap driver"
A
Arnd Bergmann 已提交
136
	depends on MACVLAN
137
	depends on INET
138
	select TAP
A
Arnd Bergmann 已提交
139 140 141 142
	help
	  This adds a specialized tap character device driver that is based
	  on the MAC-VLAN network interface, called macvtap. A macvtap device
	  can be added in the same way as a macvlan device, using 'type
143
	  macvtap', and then be accessed through the tap user space interface.
A
Arnd Bergmann 已提交
144 145 146 147

	  To compile this driver as a module, choose M here: the module
	  will be called macvtap.

148 149 150

config IPVLAN
    tristate "IP-VLAN support"
151
    depends on INET
152
    depends on IPV6 || !IPV6
M
Mahesh Bandewar 已提交
153
    depends on NETFILTER
154
    select NET_L3_MASTER_DEV
155 156 157 158 159 160 161
    ---help---
      This allows one to create virtual devices off of a main interface
      and packets will be delivered based on the dest L3 (IPv6/IPv4 addr)
      on packets. All interfaces (including the main interface) share L2
      making it transparent to the connected L2 switch.

      Ipvlan devices can be added using the "ip" command from the
162
      iproute2 package starting with the iproute2-3.19 release:
163 164 165 166 167 168

      "ip link add link <main-dev> [ NAME ] type ipvlan"

      To compile this driver as a module, choose M here: the module
      will be called ipvlan.

169 170 171 172 173 174 175 176 177 178 179 180 181
config IPVTAP
	tristate "IP-VLAN based tap driver"
	depends on IPVLAN
	depends on INET
	select TAP
	---help---
	  This adds a specialized tap character device driver that is based
	  on the IP-VLAN network interface, called ipvtap. An ipvtap device
	  can be added in the same way as a ipvlan device, using 'type
	  ipvtap', and then be accessed through the tap user space interface.

	  To compile this driver as a module, choose M here: the module
	  will be called ipvtap.
182

S
stephen hemminger 已提交
183 184
config VXLAN
       tristate "Virtual eXtensible Local Area Network (VXLAN)"
185
       depends on INET
T
Tom Herbert 已提交
186
       select NET_UDP_TUNNEL
187
       select GRO_CELLS
S
stephen hemminger 已提交
188 189 190 191 192 193 194 195 196 197
       ---help---
	  This allows one to create vxlan virtual interfaces that provide
	  Layer 2 Networks over Layer 3 Networks. VXLAN is often used
	  to tunnel virtual network infrastructure in virtualized environments.
	  For more information see:
	    http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-02

	  To compile this driver as a module, choose M here: the module
	  will be called vxlan.

198
config GENEVE
199 200
       tristate "Generic Network Virtualization Encapsulation"
       depends on INET && NET_UDP_TUNNEL
201
       depends on IPV6 || !IPV6
202
       select NET_IP_TUNNEL
203
       select GRO_CELLS
204 205 206 207 208 209 210 211 212 213
       ---help---
	  This allows one to create geneve virtual interfaces that provide
	  Layer 2 Networks over Layer 3 Networks. GENEVE is often used
	  to tunnel virtual network infrastructure in virtualized environments.
	  For more information see:
	    http://tools.ietf.org/html/draft-gross-geneve-02

	  To compile this driver as a module, choose M here: the module
	  will be called geneve.

214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230
config GTP
	tristate "GPRS Tunneling Protocol datapath (GTP-U)"
	depends on INET && NET_UDP_TUNNEL
	select NET_IP_TUNNEL
	---help---
	  This allows one to create gtp virtual interfaces that provide
	  the GPRS Tunneling Protocol datapath (GTP-U). This tunneling protocol
	  is used to prevent subscribers from accessing mobile carrier core
	  network infrastructure. This driver requires a userspace software that
	  implements the signaling protocol (GTP-C) to update its PDP context
	  base, such as OpenGGSN <http://git.osmocom.org/openggsn/). This
	  tunneling protocol is implemented according to the GSM TS 09.60 and
	  3GPP TS 29.060 standards.

	  To compile this drivers as a module, choose M here: the module
	  wil be called gtp.

231 232
config MACSEC
	tristate "IEEE 802.1AE MAC-level encryption (MACsec)"
233
	select CRYPTO
234 235
	select CRYPTO_AES
	select CRYPTO_GCM
236
	select GRO_CELLS
237 238 239
	---help---
	   MACsec is an encryption standard for Ethernet.

240 241
config NETCONSOLE
	tristate "Network console logging support"
L
Linus Torvalds 已提交
242
	---help---
243 244
	If you want to log kernel messages over the network, enable this.
	See <file:Documentation/networking/netconsole.txt> for details.
L
Linus Torvalds 已提交
245

246 247 248 249 250 251 252 253 254
config NETCONSOLE_DYNAMIC
	bool "Dynamic reconfiguration of logging targets"
	depends on NETCONSOLE && SYSFS && CONFIGFS_FS && \
			!(NETCONSOLE=y && CONFIGFS_FS=m)
	help
	  This option enables the ability to dynamically reconfigure target
	  parameters (interface, IP addresses, port numbers, MAC addresses)
	  at runtime through a userspace interface exported using configfs.
	  See <file:Documentation/networking/netconsole.txt> for details.
L
Linus Torvalds 已提交
255

256 257
config NETPOLL
	def_bool NETCONSOLE
258
	select SRCU
259 260 261 262

config NET_POLL_CONTROLLER
	def_bool NETPOLL

263
config NTB_NETDEV
264 265
	tristate "Virtual Ethernet over NTB Transport"
	depends on NTB_TRANSPORT
266

267 268 269 270 271 272 273 274 275 276 277 278 279
config RIONET
	tristate "RapidIO Ethernet over messaging driver support"
	depends on RAPIDIO

config RIONET_TX_SIZE
	int "Number of outbound queue entries"
	depends on RIONET
	default "128"

config RIONET_RX_SIZE
	int "Number of inbound queue entries"
	depends on RIONET
	default "128"
L
Linus Torvalds 已提交
280 281 282

config TUN
	tristate "Universal TUN/TAP device driver support"
283
	depends on INET
L
Linus Torvalds 已提交
284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304
	select CRC32
	---help---
	  TUN/TAP provides packet reception and transmission for user space
	  programs.  It can be viewed as a simple Point-to-Point or Ethernet
	  device, which instead of receiving packets from a physical media,
	  receives them from user space program and instead of sending packets
	  via physical media writes them to the user space program.

	  When a program opens /dev/net/tun, driver creates and registers
	  corresponding net device tunX or tapX.  After a program closed above
	  devices, driver will automatically delete tunXX or tapXX device and
	  all routes corresponding to it.

	  Please read <file:Documentation/networking/tuntap.txt> for more
	  information.

	  To compile this driver as a module, choose M here: the module
	  will be called tun.

	  If you don't know what to use this for, you don't need it.

305 306 307 308 309 310
config TAP
	tristate
	---help---
	  This option is selected by any driver implementing tap user space
	  interface for a virtual interface to re-use core tap functionality.

311 312 313 314 315 316 317 318 319 320 321 322 323 324
config TUN_VNET_CROSS_LE
	bool "Support for cross-endian vnet headers on little-endian kernels"
	default n
	---help---
	  This option allows TUN/TAP and MACVTAP device drivers in a
	  little-endian kernel to parse vnet headers that come from a
	  big-endian legacy virtio device.

	  Userspace programs can control the feature using the TUNSETVNETBE
	  and TUNGETVNETBE ioctls.

	  Unless you have a little-endian system hosting a big-endian virtual
	  machine with a legacy virtio NIC, you should say N.

325
config VETH
326
	tristate "Virtual ethernet pair device"
327
	---help---
328 329 330
	  This device is a local ethernet tunnel. Devices are created in pairs.
	  When one end receives the packet it appears on its pair and vice
	  versa.
331

332
config VIRTIO_NET
333 334
	tristate "Virtio network driver"
	depends on VIRTIO
335
	select NET_FAILOVER
336 337
	---help---
	  This is the virtual network driver for virtio.  It can be used with
338
	  QEMU based VMMs (like KVM or Xen).  Say Y or M.
339

340 341 342 343 344 345 346 347 348 349
config NLMON
	tristate "Virtual netlink monitoring device"
	---help---
	  This option enables a monitoring net device for netlink skbs. The
	  purpose of this is to analyze netlink messages with packet sockets.
	  Thus applications like tcpdump will be able to see local netlink
	  messages if they tap into the netlink device, record pcaps for further
	  diagnostics, etc. This is mostly intended for developers or support
	  to debug netlink issues. If unsure, say N.

D
David Ahern 已提交
350 351
config NET_VRF
	tristate "Virtual Routing and Forwarding (Lite)"
D
David Ahern 已提交
352
	depends on IP_MULTIPLE_TABLES
353
	depends on NET_L3_MASTER_DEV
D
David Ahern 已提交
354 355
	depends on IPV6 || IPV6=n
	depends on IPV6_MULTIPLE_TABLES || IPV6=n
D
David Ahern 已提交
356 357 358 359
	---help---
	  This option enables the support for mapping interfaces into VRF's. The
	  support enables VRF devices.

G
Gerard Garcia 已提交
360 361 362 363 364 365 366 367
config VSOCKMON
    tristate "Virtual vsock monitoring device"
    depends on VHOST_VSOCK
    ---help---
     This option enables a monitoring net device for vsock sockets. It is
     mostly intended for developers or support to debug vsock issues. If
     unsure, say N.

368 369 370 371 372 373 374 375 376 377 378
endif # NET_CORE

config SUNGEM_PHY
	tristate

source "drivers/net/arcnet/Kconfig"

source "drivers/atm/Kconfig"

source "drivers/net/caif/Kconfig"

379 380
source "drivers/net/dsa/Kconfig"

381 382 383 384
source "drivers/net/ethernet/Kconfig"

source "drivers/net/fddi/Kconfig"

385 386
source "drivers/net/hippi/Kconfig"

L
Linus Torvalds 已提交
387 388
config NET_SB1000
	tristate "General Instruments Surfboard 1000"
389
	depends on PNP
L
Linus Torvalds 已提交
390 391 392 393 394 395 396 397 398 399
	---help---
	  This is a driver for the General Instrument (also known as
	  NextLevel) SURFboard 1000 internal
	  cable modem. This is an ISA card which is used by a number of cable
	  TV companies to provide cable modem access. It's a one-way
	  downstream-only cable modem, meaning that your upstream net link is
	  provided by your regular phone modem.

	  At present this driver only compiles as a module, so say M here if
	  you have this card. The module will be called sb1000. Then read
400 401 402 403
	  <file:Documentation/networking/device_drivers/sb1000.txt> for
	  information on how to use this module, as it needs special ppp
	  scripts for establishing a connection. Further documentation
	  and the necessary scripts can be found at:
L
Linus Torvalds 已提交
404 405 406 407 408 409 410

	  <http://www.jacksonville.net/~fventuri/>
	  <http://home.adelphia.net/~siglercm/sb1000.html>
	  <http://linuxpower.cx/~cable/>

	  If you don't have this card, of course say N.

411 412
source "drivers/net/phy/Kconfig"

J
Jeff Kirsher 已提交
413 414
source "drivers/net/plip/Kconfig"

415 416
source "drivers/net/ppp/Kconfig"

J
Jeff Kirsher 已提交
417 418
source "drivers/net/slip/Kconfig"

419 420 421 422
source "drivers/s390/net/Kconfig"

source "drivers/net/usb/Kconfig"

L
Linus Torvalds 已提交
423 424
source "drivers/net/wireless/Kconfig"

425 426
source "drivers/net/wimax/Kconfig"

L
Linus Torvalds 已提交
427 428
source "drivers/net/wan/Kconfig"

429 430
source "drivers/net/ieee802154/Kconfig"

431 432 433
config XEN_NETDEV_FRONTEND
	tristate "Xen network device frontend driver"
	depends on XEN
434
	select XEN_XENBUS_FRONTEND
435 436
	default y
	help
I
Ian Campbell 已提交
437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468
	  This driver provides support for Xen paravirtual network
	  devices exported by a Xen network driver domain (often
	  domain 0).

	  The corresponding Linux backend driver is enabled by the
	  CONFIG_XEN_NETDEV_BACKEND option.

	  If you are compiling a kernel for use as Xen guest, you
	  should say Y here. To compile this driver as a module, chose
	  M here: the module will be called xen-netfront.

config XEN_NETDEV_BACKEND
	tristate "Xen backend network device"
	depends on XEN_BACKEND
	help
	  This driver allows the kernel to act as a Xen network driver
	  domain which exports paravirtual network devices to other
	  Xen domains. These devices can be accessed by any operating
	  system that implements a compatible front end.

	  The corresponding Linux frontend driver is enabled by the
	  CONFIG_XEN_NETDEV_FRONTEND configuration option.

	  The backend driver presents a standard network device
	  endpoint for each paravirtual network device to the driver
	  domain network stack. These can then be bridged or routed
	  etc in order to provide full network connectivity.

	  If you are compiling a kernel to run in a Xen network driver
	  domain (often this is domain 0) you should say Y here. To
	  compile this driver as a module, chose M here: the module
	  will be called xen-netback.
469

470
config VMXNET3
471 472
	tristate "VMware VMXNET3 ethernet driver"
	depends on PCI && INET
473 474 475
	depends on !(PAGE_SIZE_64KB || ARM64_64K_PAGES || \
		     IA64_PAGE_SIZE_64KB || MICROBLAZE_64K_PAGES || \
		     PARISC_PAGE_SIZE_64KB || PPC_64K_PAGES)
476 477 478 479
	help
	  This driver supports VMware's vmxnet3 virtual ethernet NIC.
	  To compile this driver as a module, choose M here: the
	  module will be called vmxnet3.
480

481 482 483 484 485 486 487
config FUJITSU_ES
	tristate "FUJITSU Extended Socket Network Device driver"
	depends on ACPI
	help
	  This driver provides support for Extended Socket network device
          on Extended Partitioning of FUJITSU PRIMEQUEST 2000 E2 series.

488 489 490 491 492 493 494 495 496 497 498 499
config THUNDERBOLT_NET
	tristate "Networking over Thunderbolt cable"
	depends on THUNDERBOLT && INET
	help
	  Select this if you want to create network between two
	  computers over a Thunderbolt cable. The driver supports Apple
	  ThunderboltIP protocol and allows communication with any host
	  supporting the same protocol including Windows and macOS.

	  To compile this driver a module, choose M here. The module will be
	  called thunderbolt-net.

500 501
source "drivers/net/hyperv/Kconfig"

502 503 504
config NETDEVSIM
	tristate "Simulated networking device"
	depends on DEBUG_FS
505
	depends on MAY_USE_DEVLINK
506 507 508 509 510 511 512 513
	help
	  This driver is a developer testing tool and software model that can
	  be used to test various control path networking APIs, especially
	  HW-offload related.

	  To compile this driver as a module, choose M here: the module
	  will be called netdevsim.

514 515 516 517 518 519 520 521
config NET_FAILOVER
	tristate "Failover driver"
	select FAILOVER
	help
	  This provides an automated failover mechanism via APIs to create
	  and destroy a failover master netdev and manages a primary and
	  standby slave netdevs that get registered via the generic failover
	  infrastructure. This can be used by paravirtual drivers to enable
522
	  an alternate low latency datapath. It also enables live migration of
523 524 525
	  a VM with direct attached VF by failing over to the paravirtual
	  datapath when the VF is unplugged.

526
endif # NETDEVICES