      ath10k: add thermal cooling device support · fe6f36d6
      Rajkumar Manoharan 提交于
      Thermal cooling device support is added to control the temperature
      by throttling the data transmission for the given duration. Throttling
      is done using hw MAC quiet time setting. Period, duration and offset
      from TBTT can be set up to quiet the MAC transmits for the required duty
      cycle (% of quiet duration). The thermal device allows user to configure
      duty cycle.
      
      The quiet params are derived as follows.
      	period = max(25TU, beacon interval / number of bss)
      	duration = period * duty cycle / 100
      
      Quiet mode can be disabled by setting the duty cycle to 0. The cooling
      device can be found under /sys/class/thermal/cooling_deviceX/.
      Corresponding soft link to this device can be found under phy folder.
      
      /sys/class/ieee80211/phy*/device/cooling_device.
      
      To set duty cycle as 40%,
      
      echo 40 >/sys/class/ieee80211/phy*/device/cooling_device/cur_state
      Signed-off-by: NRajkumar Manoharan <rmanohar@qti.qualcomm.com>
      Signed-off-by: NKalle Valo <kvalo@qca.qualcomm.com>