- 24 4月, 2017 2 次提交
-
-
由 James Smart 提交于
The driver with nvme had this routine stubbed. Right now XRI_ABORTED_CQE is not handled and the FC NVMET Transport has a new API for the driver. Missing code path, new NVME abort API Update ABORT processing for NVMET There are 3 new FC NVMET Transport API/ template routines for NVMET: lpfc_nvmet_xmt_fcp_release This NVMET template callback routine called to release context associated with an IO This routine is ALWAYS called last, even if the IO was aborted or completed in error. lpfc_nvmet_xmt_fcp_abort This NVMET template callback routine called to abort an exchange that has an IO in progress nvmet_fc_rcv_fcp_req When the lpfc driver receives an ABTS, this NVME FC transport layer callback routine is called. For this case there are 2 paths thru the driver: the driver either has an outstanding exchange / context for the XRI to be aborted or not. If not, a BA_RJT is issued otherwise a BA_ACC NVMET Driver abort paths: There are 2 paths for aborting an IO. The first one is we receive an IO and decide not to process it because of lack of resources. An unsolicated ABTS is immediately sent back to the initiator as a response. lpfc_nvmet_unsol_fcp_buffer lpfc_nvmet_unsol_issue_abort (XMIT_SEQUENCE_WQE) The second one is we sent the IO up to the NVMET transport layer to process, and for some reason the NVME Transport layer decided to abort the IO before it completes all its phases. For this case there are 2 paths thru the driver: the driver either has an outstanding TSEND/TRECEIVE/TRSP WQE or no outstanding WQEs are present for the exchange / context. lpfc_nvmet_xmt_fcp_abort if (LPFC_NVMET_IO_INP) lpfc_nvmet_sol_fcp_issue_abort (ABORT_WQE) lpfc_nvmet_sol_fcp_abort_cmp else lpfc_nvmet_unsol_fcp_issue_abort lpfc_nvmet_unsol_issue_abort (XMIT_SEQUENCE_WQE) lpfc_nvmet_unsol_fcp_abort_cmp Context flags: LPFC_NVMET_IOP - his flag signifies an IO is in progress on the exchange. LPFC_NVMET_XBUSY - this flag indicates the IO completed but the firmware is still busy with the corresponding exchange. The exchange should not be reused until after a XRI_ABORTED_CQE is received for that exchange. LPFC_NVMET_ABORT_OP - this flag signifies an ABORT_WQE was issued on the exchange. LPFC_NVMET_CTX_RLS - this flag signifies a context free was requested, but we are deferring it due to an XBUSY or ABORT in progress. A ctxlock is added to the context structure that is used whenever these flags are set/read within the context of an IO. The LPFC_NVMET_CTX_RLS flag is only set in the defer_relase routine when the transport has resolved all IO associated with the buffer. The flag is cleared when the CTX is associated with a new IO. An exchange can has both an LPFC_NVMET_XBUSY and a LPFC_NVMET_ABORT_OP condition active simultaneously. Both conditions must complete before the exchange is freed. When the abort callback (lpfc_nvmet_xmt_fcp_abort) is envoked: If there is an outstanding IO, the driver will issue an ABORT_WQE. This should result in 3 completions for the exchange: 1) IO cmpl with XB bit set 2) Abort WQE cmpl 3) XRI_ABORTED_CQE cmpl For this scenerio, after completion #1, the NVMET Transport IO rsp callback is called. After completion #2, no action is taken with respect to the exchange / context. After completion #3, the exchange context is free for re-use on another IO. If there is no outstanding activity on the exchange, the driver will send a ABTS to the Initiator. Upon completion of this WQE, the exchange / context is freed for re-use on another IO. Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NJohannes Thumshirn <jthumshirn@suse.de>
-
由 James Smart 提交于
When RPI is not available, driver sends WQE with invalid RPI value and rejected by HBA. lpfc 0000:82:00.3: 1:3154 BLS ABORT RSP failed, data: x3/xa0320008 and lpfc :2753 PLOGI failure DID:FFFFFA Status:x3/xa0240008 In this case, driver accesses rpi_ids array out of bounds. Fix: Check return value of lpfc_sli4_alloc_rpi(). Do not allocate lpfc_nodelist entry if RPI is not available. When RPI is not available, we will get discovery timeouts and command drops for some of the vports as seen below. lpfc :0273 Unexpected discovery timeout, vport State x0 lpfc :0230 Unexpected timeout, hba link state x5 lpfc :0111 Dropping received ELS cmd Data: x0 xc90c55 x0 Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NJohannes Thumshirn <jthumshirn@suse.de>
-
- 07 3月, 2017 1 次提交
-
-
由 James Smart 提交于
A previous change unilaterally removed the hba reset entry point from the sli3 host template. This was done to allow tape devices being used for back up from being removed. Why was this done ? When there was non-responding device on the fabric, the error escalation policy would escalate to the reset handler. When the reset handler was called, it would reset the adapter, dropping link, thus logging out and terminating all i/o's - on any target. If there was a tape device on the same adapter that wasn't in error, it would kill the tape i/o's, effectively killing the tape device state. With the reset point removed, the adapter reset avoided the fabric logout, allowing the other devices to continue to operate unaffected. A hack - yes. Hint: we really need a transport I_T nexus reset callback added to the eh process (in between the SCSI target reset and hba reset points), so a fc logout could occur to the one bad target only and stop the error escalation process. This patch commonizes the approach so it can be used for sli3 and sli4 adapters, but mandates the admin, via module parameter, specifically identify which adapters the resets are to be removed for. Additionally, bus_reset, which sends Target Reset TMFs to all targets, is also removed from the template as it too has the same effect as the adapter reset. Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NLaurence Oberman <loberman@redhat.com> Tested-by: NLaurence Oberman <loberman@redhat.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
- 23 2月, 2017 7 次提交
-
-
由 James Smart 提交于
Update copyrights to 2017 for all files touched in this patch set Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NJohannes Thumshirn <jthumshirn@suse.de> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
NVME Target: Tie in to NVME Fabrics nvmet_fc LLDD target api Adds the routines to: - register and deregister the FC port as a nvmet-fc targetport - binding of nvme queues to adapter WQs - receipt and passing of NVME LS's to transport, sending transport response - receipt of NVME FCP CMD IUs, processing FCP target io data transmission commands; transmission of FCP io response - Abort operations for tgt io exchanges [mkp: fixed space at end of file warning] Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
NVME Target: Receive buffer updates Allocates buffer pools and configures adapter interfaces to handle receive buffer (asynchronous FCP CMD ius, first burst data) from the adapter. Splits by protocol, etc. Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
NVME Target: Base modifications This set of patches adds the base modifications for NVME target support The base modifications consist of: - Additional module parameters or configuration tuning - Enablement of configuration mode for NVME target. Ties into the queueing model put into place by the initiator basemods patches. - Target-specific buffer pools, dma pools, sgl pools [mkp: fixed space at end of file] Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
NVME Initiator: Add debugfs support Adds debugfs snippets to cover the new NVME initiator functionality Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
NVME Initiator: Tie in to NVME Fabrics nvme_fc LLDD initiator api Adds the routines to: - register and deregister the FC port as a nvme-fc initiator localport - register and deregister remote FC ports as a nvme-fc remoteport - binding of nvme queues to adapter WQs - send/perform NVME LS's - send/perform NVME FCP initiator io operations Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
NVME Initiator: Base modifications This patch adds base modifications for NVME initiator support. The base modifications consist of: - Formal split of SLI3 rings from SLI-4 WQs (sometimes referred to as rings as well) as implementation now widely varies between the two. - Addition of configuration modes: SCSI initiator only; NVME initiator only; NVME target only; and SCSI and NVME initiator. The configuration mode drives overall adapter configuration, offloads enabled, and resource splits. NVME support is only available on SLI-4 devices and newer fw. - Implements the following based on configuration mode: - Exchange resources are split by protocol; Obviously, if only 1 mode, then no split occurs. Default is 50/50. module attribute allows tuning. - Pools and config parameters are separated per-protocol - Each protocol has it's own set of queues, but share interrupt vectors. SCSI: SLI3 devices have few queues and the original style of queue allocation remains. SLI4 devices piggy back on an "io-channel" concept that eventually needs to merge with scsi-mq/blk-mq support (it is underway). For now, the paradigm continues as it existed prior. io channel allocates N msix and N WQs (N=4 default) and either round robins or uses cpu # modulo N for scheduling. A bunch of module parameters allow the configuration to be tuned. NVME (initiator): Allocates an msix per cpu (or whatever pci_alloc_irq_vectors gets) Allocates a WQ per cpu, and maps the WQs to msix on a WQ # modulo msix vector count basis. Module parameters exist to cap/control the config if desired. - Each protocol has its own buffer and dma pools. I apologize for the size of the patch. Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> ---- Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
- 05 1月, 2017 1 次提交
-
-
由 James Smart 提交于
Fix Xlane dynamic LUN set for LUN priority. Dynamic changing of the priority was not getting reflected on the LUN. Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
- 18 11月, 2016 1 次提交
-
-
由 Johannes Thumshirn 提交于
Change FC drivers to use 'struct bsg_job' from bsg-lib.h instead of 'struct fc_bsg_job' from scsi_transport_fc.h and remove 'struct fc_bsg_job'. Signed-off-by: NJohannes Thumshirn <jthumshirn@suse.de> Reviewed-by: NHannes Reinecke <hare@suse.com> Acked-by: NTyrel Datwyler <tyreld@linux.vnet.ibm.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
- 09 11月, 2016 1 次提交
-
-
由 James Smart 提交于
Make lpfc_prot_mask and lpfc_prot_guard per hba parameters Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NJohannes Thumshirn <jthumshirn@suse.de> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
- 16 7月, 2016 5 次提交
-
-
由 James Smart 提交于
Copyright updates Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
Remove global lpfc_sli_mode attribute in leiu of per-hba lpfc_sli_mode Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
Remove global lpfc_delay_discovery attribute in leiu of per-hba lpfc_delay_discovery Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
Remove global lpfc_enable_npiv attribute in leiu of per-hba lpfc_enable_npiv Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
Add support for XLane LUN priority Signed-off-by: NDick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: NJames Smart <james.smart@broadcom.com> Reviewed-by: NHannes Reinecke <hare@suse.com> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
- 22 12月, 2015 2 次提交
-
-
由 James Smart 提交于
Modularize, cleanup, add comments - for FDMI code in driver Note: I don't like the comments with leading # - but as we have a lot if present, I'm deferring to handle it in one big fix later. Signed-off-by: NDick Kennedy <dick.kennedy@avagotech.com> Signed-off-by: NJames Smart <james.smart@avagotech.com> Reviewed-by: NHannes Reinicke <hare@suse.de> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
由 James Smart 提交于
Fix the FLOGI discovery logic to comply with T11 standards We weren't properly setting fabric parameters, such as R_A_TOV and E_D_TOV, when we registered the vfi object in default configs and pt2pt configs. Revise to now pass service params with the values to the firmware and ensure they are reset on link bounce. Required reworking the call sequence in the discovery threads. Signed-off-by: NDick Kennedy <dick.kennedy@avagotech.com> Signed-off-by: NJames Smart <james.smart@avagotech.com> Reviewed-by: NHannes Reinicke <hare@suse.de> Signed-off-by: NMartin K. Petersen <martin.petersen@oracle.com>
-
- 06 6月, 2015 1 次提交
-
-
由 James Smart 提交于
Signed-off-by: NDick Kennedy <dick.kennedy@avagotech.com> Signed-off-by: NJames Smart <james.smart@avagotech.com> Reviewed-by: NHannes Reinecke <hare@suse.de> Signed-off-by: NJames Bottomley <JBottomley@Odin.com>
-
- 10 4月, 2015 3 次提交
-
-
由 James Smart 提交于
Update copyright to 2015 Signed-off-by: NDick Kennedy <dick.kennedy@emulex.com> Signed-off-by: NJames Smart <james.smart@emulex.com> Reviewed-by: NHannes Reinecke <hare@suse.de> Signed-off-by: NJames Bottomley <JBottomley@Odin.com>
-
由 James Smart 提交于
Currently, the driver plays off the fact that older sli4 adapters have a different rpi access pattern that allowed for the rpi reference to be released earlier in the teardown sequence, allowing the driver to recycle the rpi value sooner. Newer sli4 adapters have a different access pattern that requires us to wait for a later mailbox completion. This changes the put call location on the newer sli4 adapters. Symptoms of the error are "0110 ELS" and the "0372 iotag" errors. Signed-off-by: NDick Kennedy <dick.kennedy@emulex.com> Signed-off-by: NJames Smart <james.smart@emulex.com> Reviewed-by: NHannes Reinecke <hare@suse.de> Signed-off-by: NJames Bottomley <JBottomley@Odin.com>
-
由 James Smart 提交于
Fix host reset escalation killing all IOs. SLI-3 adapters will use a new host template. The template differs from SLI-4 adapters in that it does not have an eh_host_reset_handler. Lpfc has traditionally never had a host_reset. The host reset handler was added when we ran into a stuck hardware condition on a SLI-4 adapter. The host_reset will reset and reinit the pci function, clearing the hardware condition. Unfortunately, the host reset handler uses attach/detach code paths, which makes scsi_add_host() and scsi_remove_host() calls. Meaning, a host_reset will completely remove the scsi_host from the system. As a new call to scsi_add_host() is made, the shost# changes, which results in completely new scsi_devices and device names. All the older scsi devices on the old shost# are now orphaned and unrecoverable. We realize we need to re-implement the host_reset_handler so the scsi_host stays registered across the host_reset, but that will be a rather lengthy effort. In the short term, we had an immediate need to restore the SLI-3 devices to their working behavior, with the easiest path being to remove their host_reset handler. Signed-off-by: NDick Kennedy <dick.kennedy@emulex.com> Signed-off-by: NJames Smart <james.smart@emulex.com> Reviewed-by: NHannes Reinecke <hare@suse.de> Signed-off-by: NJames Bottomley <JBottomley@Odin.com>
-
- 17 9月, 2014 1 次提交
-
-
由 James Smart 提交于
Fix quarantined XRI recovery qualifier state in link bounce Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NDick Kennedy <dick.kennedy@emulex.com> Signed-off-by: NChristoph Hellwig <hch@lst.de>
-
- 03 6月, 2014 3 次提交
-
-
由 James Smart 提交于
Update Copyright on changed files Signed-off-by: NJames Smart <james.smart@emulex.com> Reviewed-By: NDick Kennedy <dick.kennedy@emulex.com> Signed-off-by: NChristoph Hellwig <hch@lst.de>
-
由 James Smart 提交于
Fixed locking for scsi task management commands. Signed-off-by: NJames Smart <james.smart@emulex.com> Reviewed-By: NDick Kennedy <dick.kennedy@emulex.com> Signed-off-by: NChristoph Hellwig <hch@lst.de>
-
由 James Smart 提交于
Fix SLI4 s abort loop to process all FCP rings and under ring_lock Signed-off-by: NJames Smart <james.smart@emulex.com> Reviewed-By: NDick Kennedy <dick.kennedy@emulex.com> Signed-off-by: NChristoph Hellwig <hch@lst.de>
-
- 16 3月, 2014 3 次提交
-
-
由 James Smart 提交于
Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
由 James Smart 提交于
Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
由 James Smart 提交于
Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
- 27 6月, 2013 1 次提交
-
-
由 James Smart 提交于
Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
- 03 5月, 2013 1 次提交
-
-
由 James Smart 提交于
Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
- 10 4月, 2013 1 次提交
-
-
由 James Smart 提交于
The service parameters for the VPI/RPIs were incorrect, resulting in lower utilization Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
- 30 1月, 2013 1 次提交
-
-
由 James Smart 提交于
Fixed no-context ABTS received on unsolicited receive queue failed with BA_RJT Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
- 27 11月, 2012 1 次提交
-
-
由 James Smart 提交于
Fixed boot from san failure when SLI4 FC device presented on the same PCI bus The request_firmware interface can induce delays while looking for firmware files, even if no fw file is present. In some situations the delays exceeded scan_wait timeouts, resulting in situations in which the boot device had not been discovered in time. Boot Device does not need to be on a lpfc device. Change request_firmware use to be module paramater driven. Default is to not attempt firmware download on boot. Add sysfs parameter to invoke firmware update. Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
- 08 10月, 2012 1 次提交
-
-
由 James Smart 提交于
Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
- 15 9月, 2012 1 次提交
-
-
由 James Smart 提交于
Make compliant with FC specs by sending LOGO after ABTS timeouts Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
- 14 9月, 2012 2 次提交
-
-
由 James Smart 提交于
Signed-off-by: NJames Smart <james.smart@emulex.com> Signed-off-by: NJames Bottomley <JBottomley@Parallels.com>
-
由 James Smart 提交于