- 20 6月, 2012 5 次提交
-
-
由 Axel Lin 提交于
Return -EINVAL if pdata is NULL, otherwise we have NULL dereference bug. This patch also moves the code checking pdata earlier in lp872x_probe. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Yadwinder Singh Brar 提交于
This patch implements the .set_ramp_delay callback to set the ramp_delay on hardware for BUCK2/3/4 if ramp_delay is set in regulator constraints. This patch also do some cleaning work for unrequired members of struct max77686_data. Signed-off-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Acked-by: NMyungJoo Ham <myungjoo.ham@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Mark Brown 提交于
Fixes link failure due to devm_gpio_request_one() Reported-by: NStephen Rothwell <sfr@canb.auug.org.au> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Kim, Milo 提交于
This driver supports TI/National LP8720, LP8725 PMIC. Signed-off-by: NMilo(Woogyom) Kim <milo.kim@ti.com> Reviewed-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 19 6月, 2012 6 次提交
-
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Sangbeom Kim 提交于
The S5M8767A can't know status of ap reset. So, After AP watchdog reset, AP can't boot normally. Problem can be happened like below condition. - AP Bootable lowest voltage(vdd_arm): 0.9v - AP DVFS voltage table: 0.8v, 0.9v, 1.0v - During AP works on lowest voltage(0.8V), watchdog reset is asserted - AP can't boot, because vdd arm is still 0.8v Solution - Basic concept: After ap watchdog reset, GPIO configuration is changed by default value - S5M8767A has function of voltage control with gpio (8 levels with 3 gpios) - Set bootable voltage on level 0 -> can work with default gpio configuration - In the probing, Change voltage control level from level 0 to level 1 - Execute normal dvfs operation on level 1 - After watchdog reset, ap gpio is set by default value - PMIC operation mode is changed by ap reset (level1 -> level0) - Regardless of previous vdd_arm voltage, AP always can be booted. Signed-off-by: NSangbeom Kim <sbkim73@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Yadwinder Singh Brar 提交于
This patch converts the driver to use regulator_set_voltage_time_sel() as .set_voltage_time_sel() callback. It also sets ramp_delay as 100000 uV/us for LDOs & normal BUCKs and 27500 uV/us(default/reset value) for BUCKs[2/3/4] in regulator_desc[]. Signed-off-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
In current mapping table settings, min_uV/max_uV are always equal to volt_table[0] and volt_table[table_len -1]. Thus remove min_uV and max_uV from struct tps_info. The table based mapping with table_len == 1 means fixed voltage. So we don't need fixed flag to differentiate if it is fixed or not. This patch adds DCDC_FIXED_3300000_VSEL_table and DCDC_FIXED_1800000_VSEL_table for fixed voltage cases. So we can convert tps65023_dcdc_ops to regulator_list_voltage_table. This makes the code simpler. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
If .is_enabled callback is not implemented, regulator core assumes that the regulator is always on. Thus we don't need mc13xxx_sw_regulator_is_enabled function. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 18 6月, 2012 20 次提交
-
-
由 Mark Brown 提交于
Due to the lack of a generic clock API we'd had the 32kHz clock in the regulator driver but this is definitely a Linux-specific thing and now we have a clock API hopefully the code can be moved elsewhere. Try to avoid getting DTs deployed relying on the 32kHz clock by removing it from the bindings, grep seems to tell me it's not currently used anyway. Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Mark Brown 提交于
Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
This change makes it possible to set ramp_delay with 0.xxx mV/uS without truncation issue. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For table based mapping, we can calculate voltage difference by below equation: abs(rdev->desc->volt_table[new_selector] - rdev->desc->volt_table[old_selector]) Thus we can make regulator_set_voltage_time_sel work for table based mapping. regulator_set_voltage_time_sel() only supports linear or table based mapping. In case it is misused, also warn if neither linear nor table based mapping is used with regulator_set_voltage_time_sel(). Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Yadwinder Singh Brar 提交于
For some hardwares ramp_delay for BUCKs is a configurable parameter which can be configured through DT or board file.This patch adds ramp_delay to regulator constraints and allow user to configure it for regulators which supports this feature, through DT or board file. It will provide two ways of setting the ramp_delay for a regulator: First, by setting it as constraints in board file(for configurable regulators) and set_machine_constraints() will take care of setting it on hardware by calling(the provided) .set_ramp_delay() operation(callback). Second, by setting it as data in regulator_desc(as fixed/default ramp_delay rate) for a regulator in driver. regulator_set_voltage_time_sel() will give preference to constraints->ramp_delay while reading ramp_delay rate for regulator. Similarly users should also take care accordingly while refering ramp_delay rate(in case of implementing their private .set_voltage_time_sel() callbacks for different regulators). [Rewrote subject for 80 columns -- broonie] Signed-off-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
The min_uV and max_uV are not really used in the code and misleading because the min_uV and max_uV settings does not match the value in the voltage table. For example, we have static const unsigned int ldo_vaux3_voltages[] = { 1200000, 1500000, 1800000, 2100000, 2500000, 2750000, 2790000, 2910000, }; With below min_uV/max_uV settings for AB8500_LDO_AUX3. .min_uV = 1100000, .max_uV = 3300000, The min_uV/max_uV for AB8500_LDO_AUX3 seems copy-paste from AB8500_LDO_AUX2 and is wrong. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Also removes set_voltage_time_sel callback from ab8500_regulator_fixed_ops because the voltage won't change. ( And ab8500_regulator_fixed_ops does not implement get_voltage_sel so set_voltage_time_sel won't be called ) Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
The voltage range checking should be to ensure mc13xxx_regulators[id].voltages[0] falls with min_uV and max_uV. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For linear mappings, we can use below equation to get the voltage difference between new_selector and old_selector: abs(new_selector - old_selector) * rdev->desc->uV_step Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For fixed voltage, the n_voltages should be 1 rather than 0. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Reuse map_voltage() to get the selector of a given uV. Then we can remove wm8350_ldo_mvolts_to_val() and wm8350_dcdc_mvolts_to_val(). Also remove unused wm8350_dcdc_val_to_mvolts() function. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Call wm8350_ldo_list_voltage() instead of open code to verify selected voltage falls within specified range. Use wm8350_ldo_list_voltage() here is less error prone. wm8350_ldo_val_to_mvolts() is only used in wm8350_ldo_list_voltage now, so remove it and move the implementation to wm8350_ldo_list_voltage(). This patch also include below small changes in wm8350_ldo_map_voltage: 1. wm8350_ldo_map_voltage() returns selector, thus rename variable mV to sel. 2. Use DIV_ROUND_UP macro to calculate selector. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 14 6月, 2012 3 次提交
-
-
由 Axel Lin 提交于
This patch converts .is_enabled and .get_voltage_sel to regulator_is_enabled_regmap and regulator_get_voltage_sel_regmap. For .enable, .disable, and .set_voltage_sel, the write protect level is either 1 or 2. So we cannot use regulator_[enable|disable|set_voltage_sel]_regmap. Now we store the enable reg/mask and vsel reg/mask in regulator_desc, so we can remove enable_mask, set_vout_reg, and set_vout_mask from struct tps_info. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Adjust the equation for selector >= 15 for better readability. The equation "1700000 + ((selector - 15) * 100000)" can be interpreted by: Starting from selector 15: Steps of 100mV from 1700mV Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Sangbeom Kim 提交于
To apply delay time for voltage change, replace s5m8767_set_voltage with s5m8767_set_voltage_sel. Signed-off-by: NSangbeom Kim <sbkim73@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 13 6月, 2012 3 次提交
-
-
由 Axel Lin 提交于
Call wm8400_ldo_list_voltage() instead of open code to verify selected voltage falls within specified range. Use wm8400_ldo_list_voltage() here is less error prone. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Sangbeom Kim 提交于
As s5m8767a is revisioned, remove unnecessary buck 2,3,4 initialization routine. Signed-off-by: NSangbeom Kim <sbkim73@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 11 6月, 2012 3 次提交
-
-
由 Axel Lin 提交于
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV. The unit of ramp_delay is mV/us. Current code multiples 1000 at wrong place. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV. The unit of ramp_rate is mV/us. Thus 1000 should be multiplied. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Reviewed-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Yadwinder Singh Brar 提交于
This patch adds regulator_set_voltage_time_sel(), to move into core, the commonly used code by drivers to provide the .set_voltage_time_sel callback. It will also allow us to configure different ramp delay for different regulators easily. Signed-off-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-