- 16 3月, 2015 1 次提交
-
-
由 Marcel Holtmann 提交于
Then the local out-of-band data for LE SC pairing is requested via Read Local OOB Extended Data command, then fill in the values generated by the smp_generate_oob function. Every call of this command will overwrite previously generated values. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 15 3月, 2015 11 次提交
-
-
由 Marcel Holtmann 提交于
This adds support for the simplest possible version of Read Local OOB Extended Data management command. It includes all mandatory fields, but none of the actual pairing related ones. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The eir_append_data helper function is needed for generating the extended local OOB data fields. So move it up into the right location. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
This adds support for the simplest possible version of Read Advertising Features management command. It allows basic testing of the interface. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Changes to the global configuration updates like settings, class of device, name etc. can be received by every user. They are allowed to read them in the first place so provide the updates via events as well. Otherwise untrusted users start polling for updates and that is not a desired behavior. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Check the required trust level of each management command with the trust level of the management socket. If it does not match up, then return the newly introduced permission denied error. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The flags field for the management command table will be always initialized to zero and thus no need to do that manually. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Some management commands are safe to be accessed from any user without special permissions. First step for allowing access to any of these commands from untrusted application is to mark them accordingly. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
With the introduction of trusted socket flag for control and monitor channels, it is now possible to use a single function for sending packets to these sockets. And with that consolidate the handling. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The Read Extended Contoller Index List command can be used for retrieving the complete list of local available controllers. This included configured, unconfigured and also AMP controllers. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
This introduces support for using Extended Index Added and Extended Index Removed events. These events contain the controller type and also the hardware bus information from the driver. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
For sending Index Added, Index Removed, Unconfigured Index Added and Unconfigured Index Removed managment events the new helper functions allows taking into account if these events are enabled for a certain management socket or not. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 14 3月, 2015 1 次提交
-
-
由 Marcel Holtmann 提交于
With the extension of hdev->dev_flags utilizing a bitmap now, the space is no longer restricted. Merge the hdev->dbg_flags into hdev->dev_flags to save space on 64-bit architectures. On 32-bit architectures no size reduction happens. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 13 3月, 2015 8 次提交
-
-
由 Marcel Holtmann 提交于
Instead of manually coding test_and_set_bit on hdev->dev_flags all the time, use hci_dev_test_and_set_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding test_and_clear_bit on hdev->dev_flags all the time, use hci_dev_test_and_clear_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding test_and_change_bit on hdev->dev_flags all the time, use hci_dev_test_and_change_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding change_bit on hdev->dev_flags all the time, use hci_dev_change_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding clear_bit on hdev->dev_flags all the time, use hci_dev_clear_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding set_bit on hdev->dev_flags all the time, use hci_dev_set_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
Instead of manually coding test_bit on hdev->dev_flags all the time, use hci_dev_test_flag helper macro. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Marcel Holtmann 提交于
The patch adds a second advertising setting that allows switching of the controller into connectable mode independent of the global connectable setting. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 11 3月, 2015 3 次提交
-
-
由 Marcel Holtmann 提交于
This patch increments the management interface revision due to introduction of new static address setting and fixes for the fast connectable feature. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Johan Hedberg 提交于
To make the behavior predictable when attempting to pair with a device for which we already have a Link Key or Long Term Key, this patch adds a new 'Already Paired' error which gets sent in such a scenario. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
To maximize the usability of the Fast Connectable feature we should make it possible to set (or unset) it at any given moment. This means removing the dependency on the 'connectable' setting as well as the 'powered' setting. The former makes also sense since page scan may get enabled through add_device even if 'connectable' is false. To keep the setting available over power cycles its flag also needs to be removed from the flags that are cleared upon HCI_Reset. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
- 07 3月, 2015 7 次提交
-
-
由 Johan Hedberg 提交于
Currently the mgmt_event() function is only capable of sending to HCI_CHANNEL_CONTROL. To void having to change all users of it, add a new mgmt_send_event() function that takes a channel parameter, and make the old mgmt_event() a wrapper that passes MGMT_CHANNEL_CONTROL to it. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
This patch renames the pending_cmd struct (used for tracking pending mgmt commands) to mgmt_pending_cmd, so that it can be moved to a more generic place and be used also by other modules using other HCI channels. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
This patch renames the cmd_complete() function to mgmt_cmd_complete() in preparation of making it a generic helper for other modules to use too. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
This patch renames the cmd_status() function to mgmt_cmd_status() in preparation of making it a generic helper for other modules to use too. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
In order to completely generalize the mgmt command handling we need to move away command-specific information from mgmt_control() into the actual command table. This patch adds a new 'flags' field to the handler entries which can now contain the following command specific information: - Command takes variable length parameters - Command doesn't target any specific HCI device - Command can be sent when the HCI device is unconfigured After this the mgmt_control() function is completely generic and can potentially be reused by new HCI channels. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
This patch converts the existing mgmt code to use the newly introduced generic API for registering HCI channels with mgmt-like semantics. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Marcel Holtmann 提交于
Currently it is not possible to determine if the static address is used by the controller. It is also not possible to determine if using a static on a dual-mode controller with disabled BR/EDR is possible or not. To address this issue, introduce a new setting called static-address. If support for this setting is signaled that means that the kernel supports using static addresses. And if used on dual-mode controllers with BR/EDR disabled it means that a configured static address can be used. In addition utilize the same setting for the list of current active settings that indicates if a static address is configured and if that address will be actually used. With this in mind the existing Set Static Address management command has been extended to return the current settings. That way the caller of that command can easily determine if the programmed address will be used or if extra steps are required. Signed-off-by: NMarcel Holtmann <marcel@holtmann.org> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 05 3月, 2015 3 次提交
-
-
由 Jakub Pawlowski 提交于
This patch fixes service discovery behaviour, when provided uuid filter is empty and HCI_QUIRK_STRICT_DUPLICATE_FILTER is set. Before this patch, empty uuid filter was unable to trigger scan restart, and that caused inconsistent behaviour in applications. Example: two DBus clients call BlueZ, one to find all devices with service abcd, second to find all devices with rssi smaller than -90. Sum of those filters, that is passed to mgmt_service_scan is empty filter, with no rssi or uuids set. That caused kernel not to restart scan when quirk was set. That was inconsistent with what happen when there's only one of those two filters set (scan is restarted and reports devices). To fix that, new variable hdev->discovery.result_filtering was introduced. It can indicate that filtered scan is running, no matter what uuid or rssi filter is set. Signed-off-by: NJakub Pawlowski <jpawlowski@google.com> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Jakub Pawlowski 提交于
This patch refactor code responsible for filtering when service discovery method is used. Previously this code was mixed with mgmt_device found logic. Now when it's in one place whole logic can be greatly simplified. That includes removing no longer necessary length field and merging checks for eir and scan_rsp. Signed-off-by: NJakub Pawlowski <jpawlowski@google.com> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
由 Jakub Pawlowski 提交于
This patch moves whole packet filering logic of service discovery into new function is_filter_match. It's done because logic inside mgmt_device_found is very complicated and needs some simplification. Also having whole logic in one place will allow to simplify it in the future. Signed-off-by: NJakub Pawlowski <jpawlowski@google.com> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 28 2月, 2015 1 次提交
-
-
由 Johan Hedberg 提交于
The 'master' parameter of the New CSRK event was recently renamed to 'type', with the old values kept for backwards compatibility as unauthenticated local/remote keys. This patch updates the code to take into account the two new (authenticated) values and ensures they get used based on the security level of the connection that the respective keys get distributed over. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
- 21 2月, 2015 1 次提交
-
-
由 Johan Hedberg 提交于
The hci_send_to_control() can be made more general purpose with a small change of passing the desired HCI channel as a parameter to it. This allows using it for the monitor channel as well as e.g. 6lowpan in the future. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
- 20 2月, 2015 2 次提交
-
-
由 Johan Hedberg 提交于
Changing the HS setting requires that SSP is enabled, however so far the code only checked for the SSP flag but not a potentially ongoing Set SSP operation. This patch adds a check for a pending Set SSP command in the Set HS handler, and returns a 'busy' error if one is found. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
由 Johan Hedberg 提交于
The command handler for Set HS doesn't use mgmt_pending_add() so we can never have a pending Set HS command that mgmt_pending_find() would return. This patch removes an unnecessary lookup for it in the set_ssp() handler function. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-
- 14 2月, 2015 1 次提交
-
-
由 Lukasz Rymanowski 提交于
If user space is trying to pair on not enabled transport MGMT_STATUS_REJECT will be returned. If user space is trying to pair on transport which controller does not support, MGMT_STATUS_NOT_SUPPORTED will be returned. Having separate error code for that scenario might be useful for debugging at least. Signed-off-by: NLukasz Rymanowski <lukasz.rymanowski@tieto.com> Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com>
-
- 03 2月, 2015 1 次提交
-
-
由 Johan Hedberg 提交于
This extended return parameters struct conflicts with the new Read Local OOB Extended Data command definition. To avoid the conflict simply rename the old "extended" version to the normal one and update the code appropriately to take into account the two possible response PDU sizes. Signed-off-by: NJohan Hedberg <johan.hedberg@intel.com> Signed-off-by: NMarcel Holtmann <marcel@holtmann.org>
-