- 22 3月, 2013 1 次提交
-
-
由 Willem de Bruijn 提交于
The packetsocket fanout test uses a packet ring. Use TPACKET_V2 instead of TPACKET_V1 to work around a known 32/64 bit issue in the older ring that manifests on sparc64. Signed-off-by: NWillem de Bruijn <willemb@google.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 21 3月, 2013 3 次提交
-
-
由 David S. Miller 提交于
Suggested-by: NDaniel Baluta <daniel.baluta@gmail.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Daniel Baluta 提交于
Signed-off-by: NDaniel Baluta <dbaluta@ixiacom.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Willem de Bruijn 提交于
Fix flaky results with PACKET_FANOUT_HASH depending on whether the two flows hash into the same packet socket or not. Also adds tests for PACKET_FANOUT_LB and PACKET_FANOUT_CPU and replaces the counting method with a packet ring. Signed-off-by: NWillem de Bruijn <willemb@google.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
- 20 3月, 2013 2 次提交
-
-
由 David S. Miller 提交于
Reported-by: NDaniel Baluta <dbaluta@ixiacom.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-
由 Willem de Bruijn 提交于
Changes: v3->v2: rebase (no other changes) passes selftest v2->v1: read f->num_members only once fix bug: test rollover mode + flag Minimize packet drop in a fanout group. If one socket is full, roll over packets to another from the group. Maintain flow affinity during normal load using an rxhash fanout policy, while dispersing unexpected traffic storms that hit a single cpu, such as spoofed-source DoS flows. Rollover breaks affinity for flows arriving at saturated sockets during those conditions. The patch adds a fanout policy ROLLOVER that rotates between sockets, filling each socket before moving to the next. It also adds a fanout flag ROLLOVER. If passed along with any other fanout policy, the primary policy is applied until the chosen socket is full. Then, rollover selects another socket, to delay packet drop until the entire system is saturated. Probing sockets is not free. Selecting the last used socket, as rollover does, is a greedy approach that maximizes chance of success, at the cost of extreme load imbalance. In practice, with sufficiently long queues to absorb bursts, sockets are drained in parallel and load balance looks uniform in `top`. To avoid contention, scales counters with number of sockets and accesses them lockfree. Values are bounds checked to ensure correctness. Tested using an application with 9 threads pinned to CPUs, one socket per thread and sufficient busywork per packet operation to limits each thread to handling 32 Kpps. When sent 500 Kpps single UDP stream packets, a FANOUT_CPU setup processes 32 Kpps in total without this patch, 270 Kpps with the patch. Tested with read() and with a packet ring (V1). Also, passes psock_fanout.c unit test added to selftests. Signed-off-by: NWillem de Bruijn <willemb@google.com> Reviewed-by: NEric Dumazet <edumazet@google.com> Signed-off-by: NDavid S. Miller <davem@davemloft.net>
-