- 18 6月, 2012 15 次提交
-
-
由 Yadwinder Singh Brar 提交于
For some hardwares ramp_delay for BUCKs is a configurable parameter which can be configured through DT or board file.This patch adds ramp_delay to regulator constraints and allow user to configure it for regulators which supports this feature, through DT or board file. It will provide two ways of setting the ramp_delay for a regulator: First, by setting it as constraints in board file(for configurable regulators) and set_machine_constraints() will take care of setting it on hardware by calling(the provided) .set_ramp_delay() operation(callback). Second, by setting it as data in regulator_desc(as fixed/default ramp_delay rate) for a regulator in driver. regulator_set_voltage_time_sel() will give preference to constraints->ramp_delay while reading ramp_delay rate for regulator. Similarly users should also take care accordingly while refering ramp_delay rate(in case of implementing their private .set_voltage_time_sel() callbacks for different regulators). [Rewrote subject for 80 columns -- broonie] Signed-off-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
The min_uV and max_uV are not really used in the code and misleading because the min_uV and max_uV settings does not match the value in the voltage table. For example, we have static const unsigned int ldo_vaux3_voltages[] = { 1200000, 1500000, 1800000, 2100000, 2500000, 2750000, 2790000, 2910000, }; With below min_uV/max_uV settings for AB8500_LDO_AUX3. .min_uV = 1100000, .max_uV = 3300000, The min_uV/max_uV for AB8500_LDO_AUX3 seems copy-paste from AB8500_LDO_AUX2 and is wrong. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Also removes set_voltage_time_sel callback from ab8500_regulator_fixed_ops because the voltage won't change. ( And ab8500_regulator_fixed_ops does not implement get_voltage_sel so set_voltage_time_sel won't be called ) Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
The voltage range checking should be to ensure mc13xxx_regulators[id].voltages[0] falls with min_uV and max_uV. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For linear mappings, we can use below equation to get the voltage difference between new_selector and old_selector: abs(new_selector - old_selector) * rdev->desc->uV_step Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For fixed voltage, the n_voltages should be 1 rather than 0. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Reuse map_voltage() to get the selector of a given uV. Then we can remove wm8350_ldo_mvolts_to_val() and wm8350_dcdc_mvolts_to_val(). Also remove unused wm8350_dcdc_val_to_mvolts() function. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Call wm8350_ldo_list_voltage() instead of open code to verify selected voltage falls within specified range. Use wm8350_ldo_list_voltage() here is less error prone. wm8350_ldo_val_to_mvolts() is only used in wm8350_ldo_list_voltage now, so remove it and move the implementation to wm8350_ldo_list_voltage(). This patch also include below small changes in wm8350_ldo_map_voltage: 1. wm8350_ldo_map_voltage() returns selector, thus rename variable mV to sel. 2. Use DIV_ROUND_UP macro to calculate selector. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 14 6月, 2012 3 次提交
-
-
由 Axel Lin 提交于
This patch converts .is_enabled and .get_voltage_sel to regulator_is_enabled_regmap and regulator_get_voltage_sel_regmap. For .enable, .disable, and .set_voltage_sel, the write protect level is either 1 or 2. So we cannot use regulator_[enable|disable|set_voltage_sel]_regmap. Now we store the enable reg/mask and vsel reg/mask in regulator_desc, so we can remove enable_mask, set_vout_reg, and set_vout_mask from struct tps_info. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Adjust the equation for selector >= 15 for better readability. The equation "1700000 + ((selector - 15) * 100000)" can be interpreted by: Starting from selector 15: Steps of 100mV from 1700mV Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Sangbeom Kim 提交于
To apply delay time for voltage change, replace s5m8767_set_voltage with s5m8767_set_voltage_sel. Signed-off-by: NSangbeom Kim <sbkim73@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 13 6月, 2012 3 次提交
-
-
由 Axel Lin 提交于
Call wm8400_ldo_list_voltage() instead of open code to verify selected voltage falls within specified range. Use wm8400_ldo_list_voltage() here is less error prone. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Sangbeom Kim 提交于
As s5m8767a is revisioned, remove unnecessary buck 2,3,4 initialization routine. Signed-off-by: NSangbeom Kim <sbkim73@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 11 6月, 2012 7 次提交
-
-
由 Axel Lin 提交于
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV. The unit of ramp_delay is mV/us. Current code multiples 1000 at wrong place. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV. The unit of ramp_rate is mV/us. Thus 1000 should be multiplied. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Reviewed-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Yadwinder Singh Brar 提交于
This patch adds regulator_set_voltage_time_sel(), to move into core, the commonly used code by drivers to provide the .set_voltage_time_sel callback. It will also allow us to configure different ramp delay for different regulators easily. Signed-off-by: NYadwinder Singh Brar <yadi.brar@samsung.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
If this driver only works when pdata->num_regulators == MAX77686_REGULATORS, let's check it earlier. Also remove unused num_regulators from struct max77686_data. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
isl_fixed_ops does not implement set_voltage_sel callback, adding map_voltage here is misleading. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 08 6月, 2012 10 次提交
-
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Also adds tps6586x_ldo0_voltages mapping table for LDO0, so we can remove the hack in tps6586x_list_voltage() and convert it to regulator_list_voltage_table. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
It's a little bit hard to read that the "else" case means id == PALMAS_REG_SMPS10. if (id != PALMAS_REG_SMPS10){ do something for the cases id != PALMAS_REG_SMPS10; } else { do something for the case id == PALMAS_REG_SMPS10; } This patch changes above syntax to switch statement. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NGraeme Gregory <gg@slimlogic.co.uk> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Current code actually clears more bits than PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK bits. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NGraeme Gregory <gg@slimlogic.co.uk> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For linear mappings, we can use below equation to get the voltage difference between new_selector and old_selector: abs(new_selector - old_selector) * rdev->desc->uV_step Signed-off-by: NAxel Lin <axel.lin@gmail.com> Acked-by: NLaxman Dewangan <ldewangan@nvidia.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
For fixed voltage, DA9030_LDO13 and DA9034_LDO5, the info->vol_reg is DA9030_INVAL/DA9034_INVAL. It does not make sense to read/write to DA9030_INVAL/DA9034_INVAL address. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
Fixed voltage is a kind of linear mapping where n_voltages is 1. This change allows [list|map]_voltage_linear to be used for fixed voltage. For fixed voltage, n_voltages is 1 and the only valid selector is 0. Thus we actually don't care the uV_step setting. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
- 05 6月, 2012 2 次提交
-
-
由 Axel Lin 提交于
The voltage mapping table for LDO2 is exactly the same as VDCDCx. Thus we can use one mapping table for both LDO2 and VDCDCx instead of duplicating the mapping table. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-
由 Axel Lin 提交于
The min_uV and max_uV are not used in this driver. For table based voltage mappings, we can get min_uV and max_uV by info->table[0] and info->table[table_len -1]. Thus remove min_uV and max_uV from struct tps_info. Signed-off-by: NAxel Lin <axel.lin@gmail.com> Signed-off-by: NMark Brown <broonie@opensource.wolfsonmicro.com>
-