提交 fc80a202 编写于 作者: C Clemens Ladisch 提交者: Jaroslav Kysela

[ALSA] ymfpci: fix SPDIF sample rate information

Modules: YMFPCI driver

Set the (read only) sample rate field in the IEC958 mixer controls to
48 kHz (instead of 44.1 kHz) because that is the rate actually
supported by the hardware.
Signed-off-by: NClemens Ladisch <clemens@ladisch.de>
上级 da79e44d
......@@ -1229,6 +1229,7 @@ static int snd_ymfpci_spdif_default_get(struct snd_kcontrol *kcontrol,
spin_lock_irq(&chip->reg_lock);
ucontrol->value.iec958.status[0] = (chip->spdif_bits >> 0) & 0xff;
ucontrol->value.iec958.status[1] = (chip->spdif_bits >> 8) & 0xff;
ucontrol->value.iec958.status[3] = IEC958_AES3_CON_FS_48000;
spin_unlock_irq(&chip->reg_lock);
return 0;
}
......@@ -1303,6 +1304,7 @@ static int snd_ymfpci_spdif_stream_get(struct snd_kcontrol *kcontrol,
spin_lock_irq(&chip->reg_lock);
ucontrol->value.iec958.status[0] = (chip->spdif_pcm_bits >> 0) & 0xff;
ucontrol->value.iec958.status[1] = (chip->spdif_pcm_bits >> 8) & 0xff;
ucontrol->value.iec958.status[3] = IEC958_AES3_CON_FS_48000;
spin_unlock_irq(&chip->reg_lock);
return 0;
}
......