MIPS: Lantiq: Use the real EXIN count
We runtime load the available external interrupts into an array and store the number inside exin_avail. Some of the code however uses MAX_EIU for looping over the array which may partially be 0. This is a cosmetic fix as the existing code works as is. It is just nicer to only loop over the array elements that were actually populated during probe. Signed-off-by: NJohn Crispin <john@phrozen.org> Cc: Linux-MIPS <linux-mips@linux-mips.org> Patchwork: https://patchwork.linux-mips.org/patch/13602/Signed-off-by: NRalf Baechle <ralf@linux-mips.org>