提交 f496c09c 编写于 作者: J Jason Gerecke 提交者: Jiri Kosina

HID: wacom: generic: Ignore HID_DG_BATTERYSTRENTH == 0

AES sensors use the value 0 to indicate "not available" rather than
"completely dead". Such values are often sent for dozens of reports
while the pen is being brought into proximity and can cause userspace
to get the wrong impression about the actual battery state.
Signed-off-by: NJason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: NPing Cheng <ping.cheng@wacom.com>
Signed-off-by: NJiri Kosina <jkosina@suse.cz>
上级 37d16019
无相关合并请求
......@@ -2036,6 +2036,8 @@ static void wacom_wac_pen_event(struct hid_device *hdev, struct hid_field *field
wacom_wac->hid_data.sense_state = value;
return;
case HID_DG_BATTERYSTRENGTH:
if (value == 0) /* "not available" */
break;
value = value * 100 / (field->logical_maximum - field->logical_minimum);
wacom_wac->hid_data.battery_capacity = value;
wacom_wac->hid_data.bat_connected = 1;
......