wl1271: fix init loop timeout
The check after the loop which checks whether the initialization timed-out was wrong. If the initialization would succeed exactly in the 20000th time (the value set for INIT_LOOP), the driver would bail out and claim that initialization failed. Reported-by: NJuha Leppanen <juha_motorsportcom@luukku.com> Signed-off-by: NLuciano Coelho <luciano.coelho@nokia.com> Reviewed-by: NJanne Ylalehto <janne.ylalehto@nokia.com> Signed-off-by: NJohn W. Linville <linville@tuxdriver.com>