提交 dd470448 编写于 作者: L Lee Jones 提交者: Mike Turquette

clk: ux500: Provide device enumeration number suffix for SMSC911x

First Ethernet device has a ".0" appended onto the device name. It
appears that we need this in order to obtain the correct clock.

Without this fix Ethernet does not function on Ux500 devices, which is a
regression.

Cc: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: NLee Jones <lee.jones@linaro.org>
Signed-off-by: NMike Turquette <mturquette@linaro.org>
[mturquette@linaro.org: improved changelog]
上级 e4aa937e
......@@ -325,7 +325,7 @@ void u8500_clk_init(u32 clkrst1_base, u32 clkrst2_base, u32 clkrst3_base,
clk = clk_reg_prcc_pclk("p3_pclk0", "per3clk", clkrst3_base,
BIT(0), 0);
clk_register_clkdev(clk, "fsmc", NULL);
clk_register_clkdev(clk, NULL, "smsc911x");
clk_register_clkdev(clk, NULL, "smsc911x.0");
clk = clk_reg_prcc_pclk("p3_pclk1", "per3clk", clkrst3_base,
BIT(1), 0);
......