提交 dc040b55 编写于 作者: P Pan Bian 提交者: Greg Kroah-Hartman

ubi: Do not drop UBI device reference before using

[ Upstream commit e542087701f09418702673631a908429feb3eae0 ]

The UBI device reference is dropped but then the device is used as a
parameter of ubi_err. The bug is introduced in changing ubi_err's
behavior. The old ubi_err does not require a UBI device as its first
parameter, but the new one does.

Fixes: 32608703 ("UBI: Extend UBI layer debug/messaging capabilities")
Signed-off-by: NPan Bian <bianpan2016@163.com>
Reviewed-by: NBoris Brezillon <boris.brezillon@bootlin.com>
Signed-off-by: NRichard Weinberger <richard@nod.at>
Signed-off-by: NSasha Levin <sashal@kernel.org>
上级 d57b00ff
......@@ -227,9 +227,9 @@ struct ubi_volume_desc *ubi_open_volume(int ubi_num, int vol_id, int mode)
out_free:
kfree(desc);
out_put_ubi:
ubi_put_device(ubi);
ubi_err(ubi, "cannot open device %d, volume %d, error %d",
ubi_num, vol_id, err);
ubi_put_device(ubi);
return ERR_PTR(err);
}
EXPORT_SYMBOL_GPL(ubi_open_volume);
......