提交 d70bc0c6 编写于 作者: J Jeff Layton 提交者: J. Bruce Fields

nfsd/sunrpc: move pool_mode definitions into svc.h

In later patches, we're going to need to allow code external to svc.c
to figure out what pool_mode is in use. Move these definitions into
svc.h to prepare for that.

Also, make the svc_pool_map object available and exported so that other
modules can peek in there to get insight into what pool mode is in use.
Likewise, export svc_pool_map_get/put function to make it safe to do so.
Signed-off-by: NShirley Ma <shirley.ma@oracle.com>
Acked-by: NJeff Layton <jlayton@primarydata.com>
Tested-by: NShirley Ma <shirley.ma@oracle.com>
Signed-off-by: NJ. Bruce Fields <bfields@redhat.com>
上级 598e2359
......@@ -427,6 +427,29 @@ struct svc_procedure {
unsigned int pc_xdrressize; /* maximum size of XDR reply */
};
/*
* Mode for mapping cpus to pools.
*/
enum {
SVC_POOL_AUTO = -1, /* choose one of the others */
SVC_POOL_GLOBAL, /* no mapping, just a single global pool
* (legacy & UP mode) */
SVC_POOL_PERCPU, /* one pool per cpu */
SVC_POOL_PERNODE /* one pool per numa node */
};
struct svc_pool_map {
int count; /* How many svc_servs use us */
int mode; /* Note: int not enum to avoid
* warnings about "enumeration value
* not handled in switch" */
unsigned int npools;
unsigned int *pool_to; /* maps pool id to cpu or node */
unsigned int *to_pool; /* maps cpu or node to pool id */
};
extern struct svc_pool_map svc_pool_map;
/*
* Function prototypes.
*/
......@@ -438,6 +461,8 @@ struct svc_serv *svc_create(struct svc_program *, unsigned int,
struct svc_rqst *svc_prepare_thread(struct svc_serv *serv,
struct svc_pool *pool, int node);
void svc_exit_thread(struct svc_rqst *);
unsigned int svc_pool_map_get(void);
void svc_pool_map_put(void);
struct svc_serv * svc_create_pooled(struct svc_program *, unsigned int,
struct svc_serv_ops *);
int svc_set_num_threads(struct svc_serv *, struct svc_pool *, int);
......
......@@ -36,34 +36,17 @@ static void svc_unregister(const struct svc_serv *serv, struct net *net);
#define svc_serv_is_pooled(serv) ((serv)->sv_ops->svo_function)
/*
* Mode for mapping cpus to pools.
*/
enum {
SVC_POOL_AUTO = -1, /* choose one of the others */
SVC_POOL_GLOBAL, /* no mapping, just a single global pool
* (legacy & UP mode) */
SVC_POOL_PERCPU, /* one pool per cpu */
SVC_POOL_PERNODE /* one pool per numa node */
};
#define SVC_POOL_DEFAULT SVC_POOL_GLOBAL
/*
* Structure for mapping cpus to pools and vice versa.
* Setup once during sunrpc initialisation.
*/
static struct svc_pool_map {
int count; /* How many svc_servs use us */
int mode; /* Note: int not enum to avoid
* warnings about "enumeration value
* not handled in switch" */
unsigned int npools;
unsigned int *pool_to; /* maps pool id to cpu or node */
unsigned int *to_pool; /* maps cpu or node to pool id */
} svc_pool_map = {
.count = 0,
struct svc_pool_map svc_pool_map = {
.mode = SVC_POOL_DEFAULT
};
EXPORT_SYMBOL_GPL(svc_pool_map);
static DEFINE_MUTEX(svc_pool_map_mutex);/* protects svc_pool_map.count only */
static int
......@@ -236,7 +219,7 @@ svc_pool_map_init_pernode(struct svc_pool_map *m)
* vice versa). Initialise the map if we're the first user.
* Returns the number of pools.
*/
static unsigned int
unsigned int
svc_pool_map_get(void)
{
struct svc_pool_map *m = &svc_pool_map;
......@@ -271,7 +254,7 @@ svc_pool_map_get(void)
mutex_unlock(&svc_pool_map_mutex);
return m->npools;
}
EXPORT_SYMBOL_GPL(svc_pool_map_get);
/*
* Drop a reference to the global map of cpus to pools.
......@@ -280,7 +263,7 @@ svc_pool_map_get(void)
* mode using the pool_mode module option without
* rebooting or re-loading sunrpc.ko.
*/
static void
void
svc_pool_map_put(void)
{
struct svc_pool_map *m = &svc_pool_map;
......@@ -297,7 +280,7 @@ svc_pool_map_put(void)
mutex_unlock(&svc_pool_map_mutex);
}
EXPORT_SYMBOL_GPL(svc_pool_map_put);
static int svc_pool_map_get_node(unsigned int pidx)
{
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册