mtd: change the location of the ONFI detected log

Some strange nand chip(such as Hynix H27UBG8T2A) can pass the `ONFI` signature
check. So the log can be printed out even it is not an ONFI nand indeed.

Change this log to the end of the function. Print out the log only when we
really detect an ONFI nand.
Signed-off-by: NHuang Shijie <b32955@freescale.com>
Acked-by: NFlorian Fainelli <ffainelli@freebox.fr>
Acked-by: NBrian Norris <computersforpeace@gmail.com>
Signed-off-by: NArtem Bityutskiy <artem.bityutskiy@linux.intel.com>
Signed-off-by: NDavid Woodhouse <David.Woodhouse@intel.com>
上级 921de864
......@@ -2853,7 +2853,6 @@ static int nand_flash_detect_onfi(struct mtd_info *mtd, struct nand_chip *chip,
chip->read_byte(mtd) != 'F' || chip->read_byte(mtd) != 'I')
return 0;
pr_info("ONFI flash detected\n");
chip->cmdfunc(mtd, NAND_CMD_PARAM, 0, -1);
for (i = 0; i < 3; i++) {
chip->read_buf(mtd, (uint8_t *)p, sizeof(*p));
......@@ -2903,6 +2902,7 @@ static int nand_flash_detect_onfi(struct mtd_info *mtd, struct nand_chip *chip,
chip->options |= (NAND_NO_READRDY |
NAND_NO_AUTOINCR) & NAND_CHIPOPTIONS_MSK;
pr_info("ONFI flash detected\n");
return 1;
}
......