提交 ac981003 编写于 作者: A Alexander Duyck 提交者: Jeff Kirsher

fm10k: Only trigger data path reset if fabric is up

This change makes it so that we only trigger the data path reset if the
fabric is ready to handle traffic.  The general idea is to avoid
triggering the reset unless the switch API is ready for us.  Otherwise
we can just postpone the reset until we receive a switch ready
notification.
Signed-off-by: NAlexander Duyck <alexander.h.duyck@redhat.com>
Signed-off-by: NJacob Keller <jacob.e.keller@intel.com>
Signed-off-by: NJeff Kirsher <jeffrey.t.kirsher@intel.com>
上级 95f4f8da
......@@ -59,6 +59,11 @@ static s32 fm10k_reset_hw_pf(struct fm10k_hw *hw)
if (reg & (FM10K_DMA_CTRL_TX_ACTIVE | FM10K_DMA_CTRL_RX_ACTIVE))
return FM10K_ERR_DMA_PENDING;
/* verify the switch is ready for reset */
reg = fm10k_read_reg(hw, FM10K_DMA_CTRL2);
if (!(reg & FM10K_DMA_CTRL2_SWITCH_READY))
goto out;
/* Inititate data path reset */
reg |= FM10K_DMA_CTRL_DATAPATH_RESET;
fm10k_write_reg(hw, FM10K_DMA_CTRL, reg);
......@@ -72,6 +77,7 @@ static s32 fm10k_reset_hw_pf(struct fm10k_hw *hw)
if (!(reg & FM10K_IP_NOTINRESET))
err = FM10K_ERR_RESET_FAILED;
out:
return err;
}
......