Documentation: mfd: Update s2mps11.txt

Updated the number of LDOs and BUCKs as per the user manual.
Fixed trivial typos to improve readability.
Signed-off-by: NSachin Kamat <sachin.kamat@linaro.org>
Signed-off-by: NLee Jones <lee.jones@linaro.org>
上级 d6daef95
* Samsung S2MPS11 Voltage and Current Regulator * Samsung S2MPS11 Voltage and Current Regulator
The Samsung S2MP211 is a multi-function device which includes voltage and The Samsung S2MPS11 is a multi-function device which includes voltage and
current regulators, RTC, charger controller and other sub-blocks. It is current regulators, RTC, charger controller and other sub-blocks. It is
interfaced to the host controller using a I2C interface. Each sub-block is interfaced to the host controller using an I2C interface. Each sub-block is
addressed by the host system using different I2C slave address. addressed by the host system using different I2C slave addresses.
Required properties: Required properties:
- compatible: Should be "samsung,s2mps11-pmic". - compatible: Should be "samsung,s2mps11-pmic".
...@@ -43,7 +43,8 @@ sub-node should be of the format as listed below. ...@@ -43,7 +43,8 @@ sub-node should be of the format as listed below.
BUCK[2/3/4/6] supports disabling ramp delay on hardware, so explictly BUCK[2/3/4/6] supports disabling ramp delay on hardware, so explictly
regulator-ramp-delay = <0> can be used for them to disable ramp delay. regulator-ramp-delay = <0> can be used for them to disable ramp delay.
In absence of regulator-ramp-delay property, default ramp delay will be used. In the absence of the regulator-ramp-delay property, the default ramp
delay will be used.
NOTE: Some BUCKs share the ramp rate setting i.e. same ramp value will be set NOTE: Some BUCKs share the ramp rate setting i.e. same ramp value will be set
for a particular group of BUCKs. So provide same regulator-ramp-delay<value>. for a particular group of BUCKs. So provide same regulator-ramp-delay<value>.
...@@ -58,10 +59,10 @@ supports. Note: The 'n' in LDOn and BUCKn represents the LDO or BUCK number ...@@ -58,10 +59,10 @@ supports. Note: The 'n' in LDOn and BUCKn represents the LDO or BUCK number
as per the datasheet of s2mps11. as per the datasheet of s2mps11.
- LDOn - LDOn
- valid values for n are 1 to 28 - valid values for n are 1 to 38
- Example: LDO0, LD01, LDO28 - Example: LDO0, LD01, LDO28
- BUCKn - BUCKn
- valid values for n are 1 to 9. - valid values for n are 1 to 10.
- Example: BUCK1, BUCK2, BUCK9 - Example: BUCK1, BUCK2, BUCK9
Example: Example:
......