提交 9a004428 编写于 作者: V Viresh Kumar 提交者: Rafael J. Wysocki

cpufreq-dt: register cooling device from ->ready() callback

Currently we are calling of_cpufreq_cooling_register() from ->init() callback.
At this point of time cpufreq driver's policy isn't completely ready to be used
as few of its fields/structure/pointers aren't yet initialized.

Because of_cpufreq_cooling_register() tries to access policy with help of
cpufreq_cpu_get() and then tries to get freq-table as well, these calls fail.

To fix this, register the cooling device after the policy is ready to be used.
And the right callback for it is the newly added ->ready() one.
Signed-off-by: NViresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: NEduardo Valentin <edubezval@gmail.com>
Tested-by: NEduardo Valentin <edubezval@gmail.com>
Reviewed-by: NLukasz Majewski <l.majewski@samsung.com>
Signed-off-by: NRafael J. Wysocki <rafael.j.wysocki@intel.com>
上级 7c45cf31
......@@ -186,7 +186,6 @@ static int cpufreq_init(struct cpufreq_policy *policy)
{
struct cpufreq_dt_platform_data *pd;
struct cpufreq_frequency_table *freq_table;
struct thermal_cooling_device *cdev;
struct device_node *np;
struct private_data *priv;
struct device *cpu_dev;
......@@ -269,20 +268,6 @@ static int cpufreq_init(struct cpufreq_policy *policy)
goto out_free_priv;
}
/*
* For now, just loading the cooling device;
* thermal DT code takes care of matching them.
*/
if (of_find_property(np, "#cooling-cells", NULL)) {
cdev = of_cpufreq_cooling_register(np, policy->related_cpus);
if (IS_ERR(cdev))
dev_err(cpu_dev,
"running cpufreq without cooling device: %ld\n",
PTR_ERR(cdev));
else
priv->cdev = cdev;
}
priv->cpu_dev = cpu_dev;
priv->cpu_reg = cpu_reg;
policy->driver_data = priv;
......@@ -292,7 +277,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
if (ret) {
dev_err(cpu_dev, "%s: invalid frequency table: %d\n", __func__,
ret);
goto out_cooling_unregister;
goto out_free_cpufreq_table;
}
policy->cpuinfo.transition_latency = transition_latency;
......@@ -305,8 +290,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
return 0;
out_cooling_unregister:
cpufreq_cooling_unregister(priv->cdev);
out_free_cpufreq_table:
dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table);
out_free_priv:
kfree(priv);
......@@ -324,7 +308,8 @@ static int cpufreq_exit(struct cpufreq_policy *policy)
{
struct private_data *priv = policy->driver_data;
cpufreq_cooling_unregister(priv->cdev);
if (priv->cdev)
cpufreq_cooling_unregister(priv->cdev);
dev_pm_opp_free_cpufreq_table(priv->cpu_dev, &policy->freq_table);
clk_put(policy->clk);
if (!IS_ERR(priv->cpu_reg))
......@@ -334,6 +319,33 @@ static int cpufreq_exit(struct cpufreq_policy *policy)
return 0;
}
static void cpufreq_ready(struct cpufreq_policy *policy)
{
struct private_data *priv = policy->driver_data;
struct device_node *np = of_node_get(priv->cpu_dev->of_node);
if (WARN_ON(!np))
return;
/*
* For now, just loading the cooling device;
* thermal DT code takes care of matching them.
*/
if (of_find_property(np, "#cooling-cells", NULL)) {
priv->cdev = of_cpufreq_cooling_register(np,
policy->related_cpus);
if (IS_ERR(priv->cdev)) {
dev_err(priv->cpu_dev,
"running cpufreq without cooling device: %ld\n",
PTR_ERR(priv->cdev));
priv->cdev = NULL;
}
}
of_node_put(np);
}
static struct cpufreq_driver dt_cpufreq_driver = {
.flags = CPUFREQ_STICKY | CPUFREQ_NEED_INITIAL_FREQ_CHECK,
.verify = cpufreq_generic_frequency_table_verify,
......@@ -341,6 +353,7 @@ static struct cpufreq_driver dt_cpufreq_driver = {
.get = cpufreq_generic_get,
.init = cpufreq_init,
.exit = cpufreq_exit,
.ready = cpufreq_ready,
.name = "cpufreq-dt",
.attr = cpufreq_generic_attr,
};
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册