brcmfmac: simplify handling e-scan result firmware event
Upon handling an e-scan result event from the firmware in brcmf_cfg80211_escan_handler() the status may indicate e-scan is completed or aborted. If so brcmf_notify_escan_complete() is called. However, that function and brcmf_cfg80211_escan_handler() both log the same debug message and both enable MPC flag in the firmware. Reviewed-by: NHante Meuleman <meuleman@broadcom.com> Reviewed-by: NPieter-Paul Giesberts <pieterpg@broadcom.com> Signed-off-by: NArend van Spriel <arend@broadcom.com> Signed-off-by: NJohn W. Linville <linville@tuxdriver.com>