提交 95677a9a 编写于 作者: S Srinivas Pandruvada 提交者: Rafael J. Wysocki

PowerCap: Fix mode for energy counter

As per the documentation of powercap sysfs, energy_uj field is read only,
if it can't be reset. Currently it always allows write but will fail,
if there is no reset callback.
Changing mode field, to read only if there is no reset callback.
Signed-off-by: NSrinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reported-by: NDirk Brandewie <dirk.j.brandewie@intel.com>
Signed-off-by: NRafael J. Wysocki <rafael.j.wysocki@intel.com>
上级 08ff4cbe
......@@ -377,9 +377,14 @@ static void create_power_zone_common_attributes(
if (power_zone->ops->get_max_energy_range_uj)
power_zone->zone_dev_attrs[count++] =
&dev_attr_max_energy_range_uj.attr;
if (power_zone->ops->get_energy_uj)
if (power_zone->ops->get_energy_uj) {
if (power_zone->ops->reset_energy_uj)
dev_attr_energy_uj.attr.mode = S_IWUSR | S_IRUGO;
else
dev_attr_energy_uj.attr.mode = S_IRUGO;
power_zone->zone_dev_attrs[count++] =
&dev_attr_energy_uj.attr;
}
if (power_zone->ops->get_power_uw)
power_zone->zone_dev_attrs[count++] =
&dev_attr_power_uw.attr;
......
Markdown is supported