提交 9249e9a4 编写于 作者: S Sakari Ailus 提交者: Mauro Carvalho Chehab

[media] smiapp: The PLL calculator handles sensors with VT clocks only

No need to pretend the OP limits are there anymore.
Signed-off-by: NSakari Ailus <sakari.ailus@linux.intel.com>
Acked-by: NLaurent Pinchart <laurent.pinchart@ideasonboard.com>
Signed-off-by: NMauro Carvalho Chehab <mchehab@osg.samsung.com>
上级 63516b55
......@@ -277,16 +277,6 @@ static int smiapp_pll_update(struct smiapp_sensor *sensor)
struct smiapp_pll *pll = &sensor->pll;
int rval;
if (sensor->minfo.smiapp_profile == SMIAPP_PROFILE_0) {
/*
* Fill in operational clock divisors limits from the
* video timing ones. On profile 0 sensors the
* requirements regarding them are essentially the
* same as on VT ones.
*/
lim.op = lim.vt;
}
pll->binning_horizontal = sensor->binning_horizontal;
pll->binning_vertical = sensor->binning_vertical;
pll->link_freq =
......