[media] s5p-fimc: Ensure proper s_stream() call order in the ISP datapaths
Since the FIMC-IS firmware communicates with an image sensor directly through the ISP I2C bus controllers data streaming cannot be simply enabled from left to right or disabled from right to left along the processing pipeline. Thus a subdev index to call s_stream() on is looked up from a table, rather than doing the op call based on increasing/decreasing indexes. Signed-off-by: NSylwester Nawrocki <s.nawrocki@samsung.com> Signed-off-by: NKyungmin Park <kyungmin.park@samsung.com> Signed-off-by: NMauro Carvalho Chehab <mchehab@redhat.com>