提交 8af56be1 编写于 作者: A Andiry Xu 提交者: Greg Kroah-Hartman

USB: xHCI: handle_tx_event() refactor: process_ctrl_td

This patch moves the ctrl td processing part in handle_tx_event()
into a separate function process_ctrl_td().
Signed-off-by: NAndiry Xu <andiry.xu@amd.com>
Signed-off-by: NSarah Sharp <sarah.a.sharp@linux.intel.com>
Signed-off-by: NGreg Kroah-Hartman <gregkh@suse.de>
上级 4422da61
......@@ -1355,6 +1355,109 @@ static int finish_td(struct xhci_hcd *xhci, struct xhci_td *td,
return ret;
}
/*
* Process control tds, update urb status and actual_length.
*/
static int process_ctrl_td(struct xhci_hcd *xhci, struct xhci_td *td,
union xhci_trb *event_trb, struct xhci_transfer_event *event,
struct xhci_virt_ep *ep, int *status)
{
struct xhci_virt_device *xdev;
struct xhci_ring *ep_ring;
unsigned int slot_id;
int ep_index;
struct xhci_ep_ctx *ep_ctx;
u32 trb_comp_code;
slot_id = TRB_TO_SLOT_ID(event->flags);
xdev = xhci->devs[slot_id];
ep_index = TRB_TO_EP_ID(event->flags) - 1;
ep_ring = xhci_dma_to_transfer_ring(ep, event->buffer);
ep_ctx = xhci_get_ep_ctx(xhci, xdev->out_ctx, ep_index);
trb_comp_code = GET_COMP_CODE(event->transfer_len);
xhci_debug_trb(xhci, xhci->event_ring->dequeue);
switch (trb_comp_code) {
case COMP_SUCCESS:
if (event_trb == ep_ring->dequeue) {
xhci_warn(xhci, "WARN: Success on ctrl setup TRB "
"without IOC set??\n");
*status = -ESHUTDOWN;
} else if (event_trb != td->last_trb) {
xhci_warn(xhci, "WARN: Success on ctrl data TRB "
"without IOC set??\n");
*status = -ESHUTDOWN;
} else {
xhci_dbg(xhci, "Successful control transfer!\n");
*status = 0;
}
break;
case COMP_SHORT_TX:
xhci_warn(xhci, "WARN: short transfer on control ep\n");
if (td->urb->transfer_flags & URB_SHORT_NOT_OK)
*status = -EREMOTEIO;
else
*status = 0;
break;
default:
if (!xhci_requires_manual_halt_cleanup(xhci,
ep_ctx, trb_comp_code))
break;
xhci_dbg(xhci, "TRB error code %u, "
"halted endpoint index = %u\n",
trb_comp_code, ep_index);
/* else fall through */
case COMP_STALL:
/* Did we transfer part of the data (middle) phase? */
if (event_trb != ep_ring->dequeue &&
event_trb != td->last_trb)
td->urb->actual_length =
td->urb->transfer_buffer_length
- TRB_LEN(event->transfer_len);
else
td->urb->actual_length = 0;
xhci_cleanup_halted_endpoint(xhci,
slot_id, ep_index, 0, td, event_trb);
return finish_td(xhci, td, event_trb, event, ep, status, true);
}
/*
* Did we transfer any data, despite the errors that might have
* happened? I.e. did we get past the setup stage?
*/
if (event_trb != ep_ring->dequeue) {
/* The event was for the status stage */
if (event_trb == td->last_trb) {
if (td->urb->actual_length != 0) {
/* Don't overwrite a previously set error code
*/
if ((*status == -EINPROGRESS || *status == 0) &&
(td->urb->transfer_flags
& URB_SHORT_NOT_OK))
/* Did we already see a short data
* stage? */
*status = -EREMOTEIO;
} else {
td->urb->actual_length =
td->urb->transfer_buffer_length;
}
} else {
/* Maybe the event was for the data stage? */
if (trb_comp_code != COMP_STOP_INVAL) {
/* We didn't stop on a link TRB in the middle */
td->urb->actual_length =
td->urb->transfer_buffer_length -
TRB_LEN(event->transfer_len);
xhci_dbg(xhci, "Waiting for status "
"stage event\n");
return 0;
}
}
}
return finish_td(xhci, td, event_trb, event, ep, status, false);
}
/*
* If this function returns an error condition, it means it got a Transfer
* event with a corrupted Slot ID, Endpoint ID, or TRB DMA address.
......@@ -1482,84 +1585,9 @@ static int handle_tx_event(struct xhci_hcd *xhci,
/* Now update the urb's actual_length and give back to the core */
/* Was this a control transfer? */
if (usb_endpoint_xfer_control(&td->urb->ep->desc)) {
xhci_debug_trb(xhci, xhci->event_ring->dequeue);
switch (trb_comp_code) {
case COMP_SUCCESS:
if (event_trb == ep_ring->dequeue) {
xhci_warn(xhci, "WARN: Success on ctrl setup TRB without IOC set??\n");
status = -ESHUTDOWN;
} else if (event_trb != td->last_trb) {
xhci_warn(xhci, "WARN: Success on ctrl data TRB without IOC set??\n");
status = -ESHUTDOWN;
} else {
xhci_dbg(xhci, "Successful control transfer!\n");
status = 0;
}
break;
case COMP_SHORT_TX:
xhci_warn(xhci, "WARN: short transfer on control ep\n");
if (td->urb->transfer_flags & URB_SHORT_NOT_OK)
status = -EREMOTEIO;
else
status = 0;
break;
default:
if (!xhci_requires_manual_halt_cleanup(xhci,
ep_ctx, trb_comp_code))
break;
xhci_dbg(xhci, "TRB error code %u, "
"halted endpoint index = %u\n",
trb_comp_code, ep_index);
/* else fall through */
case COMP_STALL:
/* Did we transfer part of the data (middle) phase? */
if (event_trb != ep_ring->dequeue &&
event_trb != td->last_trb)
td->urb->actual_length =
td->urb->transfer_buffer_length
- TRB_LEN(event->transfer_len);
else
td->urb->actual_length = 0;
xhci_cleanup_halted_endpoint(xhci,
slot_id, ep_index, 0, td, event_trb);
ret = finish_td(xhci, td, event_trb, event, ep,
&status, true);
goto cleanup;
}
/*
* Did we transfer any data, despite the errors that might have
* happened? I.e. did we get past the setup stage?
*/
if (event_trb != ep_ring->dequeue) {
/* The event was for the status stage */
if (event_trb == td->last_trb) {
if (td->urb->actual_length != 0) {
/* Don't overwrite a previously set error code */
if ((status == -EINPROGRESS ||
status == 0) &&
(td->urb->transfer_flags
& URB_SHORT_NOT_OK))
/* Did we already see a short data stage? */
status = -EREMOTEIO;
} else {
td->urb->actual_length =
td->urb->transfer_buffer_length;
}
} else {
/* Maybe the event was for the data stage? */
if (trb_comp_code != COMP_STOP_INVAL) {
/* We didn't stop on a link TRB in the middle */
td->urb->actual_length =
td->urb->transfer_buffer_length -
TRB_LEN(event->transfer_len);
xhci_dbg(xhci, "Waiting for status stage event\n");
goto cleanup;
}
}
}
ret = process_ctrl_td(xhci, td, event_trb, event, ep,
&status);
goto cleanup;
} else {
switch (trb_comp_code) {
case COMP_SUCCESS:
......
Markdown is supported
0% .
You are about to add 0 people to the discussion. Proceed with caution.
先完成此消息的编辑!
想要评论请 注册